ADJUSTMENT, REMOVAL AND REPLACEMENT PROCEDURES

NOTE. Read the instructions throughly
before performing any of the following
adjustment or removal and replacement pro-
cedure.
A.
ADJUSTEMENT OF THE EVAPORATOR
WATER LEVEL
The correct water level in the freezing cylinder is
about 20 mm. (1") below the ice discharge
opening. Low water level causes excessive strain
inside the freezer assembly due to a faster freezing
rate.
When the water level is above or below the
correct one, adjustment can be performed by
raising or lowering at the measure required, the
water reservoir and its mounting bracket.
To Raise or Lower the water level:
a. Loosen and remove the screw securing the
mounting bracket of the water reservoir to the unit
cabinet and raise the water reservoir to the correct
level.
b. Thread the mounting screw in the corresponding
hole and tighten it.
WARNING. Be sure the electrical power
supply circuit breaker and the inlet water
supply are OFF, before starting any of the
following Removal and Replacement
procedures as a precaution to prevent
possible personal injury or damage to the
equipments.
B.
REPLACEMENT OF THE GEAR MOTOR
MAGNETIC SENSOR
1.
Remove the front/top and side/rear panels.
2.
Unloose the three screws securing the
plastic cover to the top of the gear motor and
remove it.
3.
Unloose the two screws securing the
magnetic sensor to the plastic housing and
withdraw it from its seat.
4.
Trace the gear motor magnetic sensor
terminal plug on the rear side of the control box
(red with four terminal pins) and draw it out from
its socket by carefully slackening the fastening
tie.
5.
To install the replacement gear motor
magnetic sensor follow the above steps in reverse.
0.5-1.0 mm
C.
REPLACEMENT OF THE AUGER,
WATER SEAL, BEARINGS AND
COUPLING
1.
Remove the panels.
2.
Remove ice spout insulation then the ice
spout.
3.
Unloose and remove the four bolts securing
the ice breaker to the upper flange of the
evaporator.
4.
With two flat screwdrivers insert then on the
space between the icebreaker and the upper
flange and by tilting them lift the icebreaker and
auger assembly.
Grasp the icebreaker and remove the icebreaker
and auger assembly by lifting them from the
evaporator.
NOTE. If the auger cannot be pulled out,
proceed to steps 10 and 11 of this paragraph,
to gain access to the auger bottom. Then,
with a rowhide mallet or placing a piece of
wood on the bottom end of the auger, tap this
bottom to break loose the auger and be able
then to pull it out as per step 4 above.
5.
Remove the plastic cap using a screwdriver
as a lever.