Lighting Instructions - COZY DVCF402D Owner's Manual

Counterflow direct vent gas wall heater
Table of Contents

Advertisement

Available languages

Available languages

NOTE: FOR ADDITIONAL INFORMATION REFER TO
THE INSTALLATION AND OPERATION INSTRUCTION
MANUAL SUPPLIED WITH THIS APPLIANCE OR
CONTACT THE MANUFACTURER IDENTIFYING THE
PRODUCT BY ITS MODEL NUMBER LOCATED ON THE
RATING PLATE, FOUND NEAR THE GAS VALVE.

Lighting Instructions

STOP! Read the safety information above.
1.
2.
Set the thermostat to lowest setting.
3.
Turn off all electric power to the appliance.
4.
Remove control access panel.
5.
Turn the gas control knob clockwise to "OFF".
6.
Wait five (5) minutes to clear out any gas, then smell
for gas, including near the floor. If you then smell
gas, stop! Follow "B" In the safety information above. If
you don't smell gas, go to the next step.
7.
Loosen wing nut and open pilot observation door
(If equipped).
8.
To find the pilot, follow the metal tube from the gas
control valve. The pilot is mounted on the side of
the burner.
9.
Turn knob on gas control
counterclockwise to "PILOT."
10. Push in the red reset button
all the way and hold in. Immediately
light the pilot. Continue to hold the red reset button in
for about (1) minute after the pilot is lit. Release button
and it will pop back up. Pilot should remain lit. If it goes
out, repeat steps 5 through 10.
If button does not pop up when released, stop and
immediately call your service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the
gas control knob to "OFF" and call your service
technician or gas supplier.
11.
Close the pilot observation door and tighten wing nut
(if equipped).
12. Turn gas control knob counterclockwise to "ON". The
knob can be turned to "ON" only if red reset button is up.
13. Replace the control access panel.
14. Turn on all electric power to the appliance.
15. Set thermostat to the desired setting.
To Turn OFF GAS to appliance
1.
Set the thermostat to lowest setting.
2.
Turn off all electric power to the appliance if service is
to be performed (if applicable).
3.
Remove the control access panel.
4. Push in the gas control knob slightly and turn it
clockwise to "OFF". Do not force.
5.
Replace the control access panel.
IMPORTANT: KEEP BURNER AND CONTROL
COMPARTMENT CLEAN.
WARNING: DUE TO HIGH SURFACE
TEMPERATURES - KEEP CHILDREN, CLOTHING,
FURNITURE OR ANY COMBUSTIBLE MATERIAL AWAY
FROM THE FURNACE.
COUNTERFLOW DIRECT VENT GAS WALL HEATER
21