Alarm

4.7.1

Alarm Connections

In the event of an alarm, the unit can automatically connect to a pre-defined IP address. The
unit can contact up to ten IP addresses in the order listed until a connection is made.
Connect on alarm
Select On so that the unit automatically connects to a pre-defined IP address in the event of
an alarm.
Select Follows input 1 so that the unit maintains the connection for as long as an alarm exists
on alarm input 1.
Auto-connect
Select On to automatically re-establish a connection to one of the previously specified IP
addresses after each reboot, connection breakdown, or network failure.
Number of destination IP address
Specify the numbers of the IP addresses to be contacted in the event of an alarm. The unit
contacts the remote locations one after the other in the numbered sequence until a
connection is made.
Destination IP address
For each number, enter the corresponding IP address for the desired remote station.
Destination password
If the remote station is password protected, enter the password here.
Only ten passwords can be defined here. Define a general password if more than ten
connections are required. The unit connects to all remote stations protected by the same
general password. To define a general password:
1.
2.
3.
4.
Setting destination 10 to the IP-address 0.0.0.0 overrides its function as the tenth address to
try.
Video transmission
If the unit is operated behind a firewall, select TCP (HTTP port) as the transfer protocol. For
use in a local network, select UDP.
To enable multicast operation, select UDP for the Video transmission parameter here and on
the Network Access page.
Note:
In the event of an alarm, a larger network bandwidth is sometimes required for additional
video streams (if multicast operation is not possible).
Stream
Select a stream to be transmitted.
2021-08 | V01 | DOC
Select 10 in the Number of destination IP address list box.
Enter 0.0.0.0 in the Destination IP address field.
Enter the password in the Destination password field.
Set the user password of all the remote stations to be accessed using this password.