Alarm connector
Pin
1
2
3
4
•
Max. wire diameter AWG 22-28 for both stranded and solid
•
Default relay position n.o. (normally open), no alarm
•
Alarm output relay switching capability: Max voltage 30VAC or
+40VDC. Max 0.5 A continuous, 10VA.
•
Alarm in: TTL logic, +5V nominal, +40VDC max, DC coupled with
22kΩ pull-up to +3.3V
•
Alarm in: configurable as active low or active high
•
Max. 42V allowed between camera ground and each of the relay pins.
Lens mounting
The camera accepts both C and CS-mount lenses. DC-iris lenses are
recommended for the best picture performance. The camera automatically
detects the type of lens used and optimizes performance accordingly. A
spare male lens connector is provided.
Caution
To avoid damaging the CCD sensor when using a C-mount lens,
turn the red back focus ring counterclockwise until it stops (see
back focus adjustment) before mounting the lens.
Lenses weighing more than 0.5 kg (1.1lbs) must be separately
supported.
Bosch Security Systems | 2003-10 | V0.5
Alarm socket
Ground
Alarm in
Relay out contact 1
Relay out contact 2
EN | 10
Alarm
Pin 1
Pin 4