Bosch DINION XF LTC 0495 Installation Manual

Bosch DINION XF LTC 0495 Installation Manual

15-bit digital day/night camera dinion xf ltc 0620/0495 series;
Hide thumbs Also See for DINION XF LTC 0495:

Advertisement

XF
Dinion
Installation Instructions
15-bit digital day/night
EN
camera
Manuale d'installation
Caméra numérique jour/nuit
FR
15 bits
Installationshandbuch
15-Bit digitale Tag-/Nacht-
DE
Kamera
Manual de instalación
Cámara día/noche digital
ES
de 15 bits
LTC 0620 & LTC 0495 series Day/Night cameras
Installatiehandleiding
15-bits digitale dag/nacht-
NL
camera
Manuale di installazione
Telecamera giorno/notte
IT
digitale 15 bit
Manual de Instalação
Câmara digital dia/noite
PT
de 15 bits
安装说明
15 位数码日夜两用型摄像机
ZH

Advertisement

Table of Contents
loading

Summary of Contents for Bosch DINION XF LTC 0495

  • Page 1 Dinion – LTC 0620 & LTC 0495 series Day/Night cameras Installation Instructions Installatiehandleiding 15-bit digital day/night 15-bits digitale dag/nacht- camera camera Manuale d’installation Manuale di installazione Telecamera giorno/notte Caméra numérique jour/nuit 15 bits digitale 15 bit Installationshandbuch Manual de Instalação Câmara digital dia/noite 15-Bit digitale Tag-/Nacht- Kamera...
  • Page 2: Safety Precautions

    7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other equipment (including amplifiers) that produce heat. Bosch Security Systems | 2004-01 | V1.0...
  • Page 3 To reduce the risk of fire or electric shock, this apparatus should not be exposed to rain or moisture and objects filled with liquids, such as vases, should not be placed on this apparatus. Bosch Security Systems | 2004-01 | V1.0...
  • Page 4: Fcc Information

    Bosch could void the user's authority to operate the equipment. For additional information or to speak to a representative, please contact the Bosch Security Systems location nearest to you or visit our web site at www.boschsecuritysystems.com Bosch Security Systems | 2004-01 | V1.0...
  • Page 5: Type Number Overview

    NTSC NTSC Supply voltage 24 VAC or 12 VDC 230 VAC 50Hz 110 VAC 60Hz CCD type 1/3" Caution Ensure that your power supply matches the rated voltage of your camera before installing. Bosch Security Systems | 2004-01 | V1.0...
  • Page 6 CCD protection cap • Spare lens connector (male) • These instructions Note If equipment appears to have been damaged during shipment, repack it in the original packaging and notify the shipping agent or supplier. Bosch Security Systems | 2004-01 | V1.0...
  • Page 7: Composite Video

    (these connections are not polarity sensitive). • use AWG16 to 22 stranded wire or AWG16 to 26 solid wire; cut back 10mm (0.4") of insulation. Composite video Bosch Security Systems | 2004-01 | V1.0...
  • Page 8 Dinion | Installation Manual EN | 8 Sync Y/C socket GND Y GND C Bosch Security Systems | 2004-01 | V1.0...
  • Page 9: Alarm Connector

    To avoid damaging the CCD sensor when using a C-mount lens, make sure the supplied lens adapter ring is mounted onto the camera before mounting the lens. Lenses weighing more than 0.5 kg (1. 1 lbs) must be separately supported. Bosch Security Systems | 2004-01 | V1.0...
  • Page 10 If a short circuit is detected on the lens connector, the on-screen display (OSD) failure message LENS SHORT CIRCUIT is shown. The lens circuit is automatically disabled to avoid internal damage. Remove the lens connector and check the pin connections. Bosch Security Systems | 2004-01 | V1.0...
  • Page 11: Back Focus Adjustment

    To adjust back focus: Open the slide door at the side of the camera Unlock the back focus locking button. Turn the back focus adjustment as required. Lock the back focus locking button. Bosch Security Systems | 2004-01 | V1.0...
  • Page 12: Mounting The Camera

    There are four different methods of switching: • via the alarm input, • via Bilinx™ communication, • as part of the programmable mode profile, or • automatically, based on the observed light levels. Bosch Security Systems | 2004-01 | V1.0...
  • Page 13: Advanced Setup

    You can also set up Bilinx™ so that the camera buttons remain disabled even when Bilinx™ is not actively controlling the camera. This prevents unauthorized change of the camera settings. Bosch Security Systems | 2004-01 | V1.0...
  • Page 14: Menu Structure

    Day/Night Autoblack Switch level Blacklevel Priority Contour IR Contrast Mono burst XF-dynamic COLOR White balance WB speed R-gain G-gain B-gain Saturation Area BLC level BLC area Area Area Active Motion Sensitivity DEFAULTS Confirm Bosch Security Systems | 2004-01 | V1.0...
  • Page 15 Sync input Alarm in Communication Active Cable comp Action Comp level Alarm out Alarm Sync Sync Detected sync V phase H phase Subphase Camera ID Camera ID ID position MAC address All Defaults Confirm Bosch Security Systems | 2004-01 | V1.0...
  • Page 16 When in a menu, quickly pressing the menu/select key twice restores the selected item to its factory default. • To close all menus at once from any menu, select the Exit item and hold down the menu/select key until the menu display disappears. Bosch Security Systems | 2004-01 | V1.0...
  • Page 17: Mode Menu

    -15 - 0 - +15 Adjust the balance between peak and average AVERAGE video control ALC SPEED Slow, Medium, Fast Adjust the speed of the video level control loop. EXIT Return to MODE menu Bosch Security Systems | 2004-01 | V1.0...
  • Page 18 If SENS UP is active, some noise or spots may appear in the picture. This is normal camera behavior. SENS UP may cause some motion blur on moving objects. If the camera is in monochrome mode, all color related menu items are disabled and cannot be accessed. Bosch Security Systems | 2004-01 | V1.0...
  • Page 19 This may cause some motion blur on moving objects. XF-DYN OFF, LOW, In XF-DYN mode the camera automatically (dynamic range enhancement) MID, HIGH optimizes the contrast in the picture. EXIT Return to Mode menu Bosch Security Systems | 2004-01 | V1.0...
  • Page 20: Color Submenu

    Return to Mode menu Selecting an area To set-up an area for BLC (or VMD), access the area menu by selecting the AREA option from the BLC (or VMD) menu. Upon entering the AREA Bosch Security Systems | 2004-01 | V1.0...
  • Page 21: Defaults Submenu

    Selection Description MODE Select to restore the factory defaults. A DEFAULTS confirmation screen appears. Allow 5 seconds for the camera to optimize the picture after a mode reset. EXIT Return to Mode menu Bosch Security Systems | 2004-01 | V1.0...
  • Page 22: Install Menu

    Unlock the back focus locking button. Access the Lens Wizard menu. SET BACK FOCUS NOW is highlighted in the menu. Turn the back focus adjustment as required. Lock the back focus locking button. Exit the menu. Bosch Security Systems | 2004-01 | V1.0...
  • Page 23 1000m (3000ft). For optimum results select the coaxial cable type used or if unknown, DEFAULT. COMP 0, 1, .. +15 Sets the level of cable compensation. LEVEL ALARM Select submenu EXIT Return to the INSTALL menu Bosch Security Systems | 2004-01 | V1.0...
  • Page 24 Adjusts the sub-carrier phase offset (when in EXT PHASE LOCK mode and a valid sub-carrier is detected). EXIT Return to the INSTALL menu Note VPHASE, HPHASE and SUB-PHASE cannot be accessed if there is no valid locking signal. Bosch Security Systems | 2004-01 | V1.0...
  • Page 25 To avoid loss of communication on an installed camera, the COMMUNICATION ON/OFF selection is NOT available while using remote control. This function can only be accessed with the camera buttons. Bosch Security Systems | 2004-01 | V1.0...
  • Page 26: Technical Specification

    > 50 dB Video output 1 Vpp, 75 Ohm Y/C output Y: 1 Vpp C: 0.3 Vpp Synchronization Internal, HV-lock, Genlock or Line Lock selectable Shutter AES (1/60 (1/50) to 1/100000), Flickerless, Fixed selectable Bosch Security Systems | 2004-01 | V1.0...
  • Page 27 58 x 66 x 122 mm (HxWxL) without lens Weight 450g without lens Tripod Mount Bottom (isolated) and Top ¼" 20 UNC Operating -20° to 50° C temperature Controls OSD with softkey operation Bosch Security Systems | 2004-01 | V1.0...
  • Page 28 1/3" DC-iris, 3.5-8mm F1.4-300 - IR • LTC 3364/40 1/3" DC-iris, 2.8-12mm F1.4-360 • LTC 3374/20 1/3" DC-iris, 5-50mm F1.4-185 Zoom lenses: • LTC 3283/20 1/2" Video iris, 8-48mm F1.4-360 • LTC 3384/21 1/3" DC-iris, 6-60mm F1.4-360 Bosch Security Systems | 2004-01 | V1.0...
  • Page 29 Bosch Sicherheitssysteme GmbH Bosch Security Systems B.V. Ludwig-Bölkow-Allee P.O. Box 80002 5600 JB Eindhoven 85521 Ottobrunn Germany The Netherlands www.bosch-sicherheitssysteme.de www.boschsecuritysystems.com © 2004 Bosch Security Systems B.V. Subject to change. Printed in Portugal. 3122 165 23061...

Table of Contents