7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other equipment (including amplifiers) that produce heat. Bosch Security Systems | 2004-01 | V1.0...
Page 3
To reduce the risk of fire or electric shock, this apparatus should not be exposed to rain or moisture and objects filled with liquids, such as vases, should not be placed on this apparatus. Bosch Security Systems | 2004-01 | V1.0...
Bosch could void the user's authority to operate the equipment. For additional information or to speak to a representative, please contact the Bosch Security Systems location nearest to you or visit our web site at www.boschsecuritysystems.com Bosch Security Systems | 2004-01 | V1.0...
NTSC NTSC Supply voltage 24 VAC or 12 VDC 230 VAC 50Hz 110 VAC 60Hz CCD type 1/3" Caution Ensure that your power supply matches the rated voltage of your camera before installing. Bosch Security Systems | 2004-01 | V1.0...
Page 6
CCD protection cap • Spare lens connector (male) • These instructions Note If equipment appears to have been damaged during shipment, repack it in the original packaging and notify the shipping agent or supplier. Bosch Security Systems | 2004-01 | V1.0...
(these connections are not polarity sensitive). • use AWG16 to 22 stranded wire or AWG16 to 26 solid wire; cut back 10mm (0.4") of insulation. Composite video Bosch Security Systems | 2004-01 | V1.0...
Page 8
Dinion | Installation Manual EN | 8 Sync Y/C socket GND Y GND C Bosch Security Systems | 2004-01 | V1.0...
To avoid damaging the CCD sensor when using a C-mount lens, make sure the supplied lens adapter ring is mounted onto the camera before mounting the lens. Lenses weighing more than 0.5 kg (1. 1 lbs) must be separately supported. Bosch Security Systems | 2004-01 | V1.0...
Page 10
If a short circuit is detected on the lens connector, the on-screen display (OSD) failure message LENS SHORT CIRCUIT is shown. The lens circuit is automatically disabled to avoid internal damage. Remove the lens connector and check the pin connections. Bosch Security Systems | 2004-01 | V1.0...
To adjust back focus: Open the slide door at the side of the camera Unlock the back focus locking button. Turn the back focus adjustment as required. Lock the back focus locking button. Bosch Security Systems | 2004-01 | V1.0...
There are four different methods of switching: • via the alarm input, • via Bilinx™ communication, • as part of the programmable mode profile, or • automatically, based on the observed light levels. Bosch Security Systems | 2004-01 | V1.0...
You can also set up Bilinx™ so that the camera buttons remain disabled even when Bilinx™ is not actively controlling the camera. This prevents unauthorized change of the camera settings. Bosch Security Systems | 2004-01 | V1.0...
Day/Night Autoblack Switch level Blacklevel Priority Contour IR Contrast Mono burst XF-dynamic COLOR White balance WB speed R-gain G-gain B-gain Saturation Area BLC level BLC area Area Area Active Motion Sensitivity DEFAULTS Confirm Bosch Security Systems | 2004-01 | V1.0...
Page 15
Sync input Alarm in Communication Active Cable comp Action Comp level Alarm out Alarm Sync Sync Detected sync V phase H phase Subphase Camera ID Camera ID ID position MAC address All Defaults Confirm Bosch Security Systems | 2004-01 | V1.0...
Page 16
When in a menu, quickly pressing the menu/select key twice restores the selected item to its factory default. • To close all menus at once from any menu, select the Exit item and hold down the menu/select key until the menu display disappears. Bosch Security Systems | 2004-01 | V1.0...
-15 - 0 - +15 Adjust the balance between peak and average AVERAGE video control ALC SPEED Slow, Medium, Fast Adjust the speed of the video level control loop. EXIT Return to MODE menu Bosch Security Systems | 2004-01 | V1.0...
Page 18
If SENS UP is active, some noise or spots may appear in the picture. This is normal camera behavior. SENS UP may cause some motion blur on moving objects. If the camera is in monochrome mode, all color related menu items are disabled and cannot be accessed. Bosch Security Systems | 2004-01 | V1.0...
Page 19
This may cause some motion blur on moving objects. XF-DYN OFF, LOW, In XF-DYN mode the camera automatically (dynamic range enhancement) MID, HIGH optimizes the contrast in the picture. EXIT Return to Mode menu Bosch Security Systems | 2004-01 | V1.0...
Return to Mode menu Selecting an area To set-up an area for BLC (or VMD), access the area menu by selecting the AREA option from the BLC (or VMD) menu. Upon entering the AREA Bosch Security Systems | 2004-01 | V1.0...
Selection Description MODE Select to restore the factory defaults. A DEFAULTS confirmation screen appears. Allow 5 seconds for the camera to optimize the picture after a mode reset. EXIT Return to Mode menu Bosch Security Systems | 2004-01 | V1.0...
Unlock the back focus locking button. Access the Lens Wizard menu. SET BACK FOCUS NOW is highlighted in the menu. Turn the back focus adjustment as required. Lock the back focus locking button. Exit the menu. Bosch Security Systems | 2004-01 | V1.0...
Page 23
1000m (3000ft). For optimum results select the coaxial cable type used or if unknown, DEFAULT. COMP 0, 1, .. +15 Sets the level of cable compensation. LEVEL ALARM Select submenu EXIT Return to the INSTALL menu Bosch Security Systems | 2004-01 | V1.0...
Page 24
Adjusts the sub-carrier phase offset (when in EXT PHASE LOCK mode and a valid sub-carrier is detected). EXIT Return to the INSTALL menu Note VPHASE, HPHASE and SUB-PHASE cannot be accessed if there is no valid locking signal. Bosch Security Systems | 2004-01 | V1.0...
Page 25
To avoid loss of communication on an installed camera, the COMMUNICATION ON/OFF selection is NOT available while using remote control. This function can only be accessed with the camera buttons. Bosch Security Systems | 2004-01 | V1.0...
> 50 dB Video output 1 Vpp, 75 Ohm Y/C output Y: 1 Vpp C: 0.3 Vpp Synchronization Internal, HV-lock, Genlock or Line Lock selectable Shutter AES (1/60 (1/50) to 1/100000), Flickerless, Fixed selectable Bosch Security Systems | 2004-01 | V1.0...
Page 27
58 x 66 x 122 mm (HxWxL) without lens Weight 450g without lens Tripod Mount Bottom (isolated) and Top ¼" 20 UNC Operating -20° to 50° C temperature Controls OSD with softkey operation Bosch Security Systems | 2004-01 | V1.0...