Assembly And Installation - Delta PMT2 150 W Series Technical Data Sheet

Panel mount power supply
Table of Contents

Advertisement

TECHNICAL DATASHEET
PMT2 Panel Mount Power Supply
PMT2 150 W series / PMT-□V150W2B□□
Assembly & Installation
Ⓐ Mounting holes for power supply
The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5 mm (0.20 inch) length.
Ⓑ This surface belongs to customer's end system or panel where the power supply is mounted.
Ⓒ Connector
* If the device has to be mounted in any other orientation, please contact info@deltapsu.com for more details.
Use flexible cable (stranded or solid) of AWG No. 18-12. User should calculate and select the suitable wire specification
(type/quantity/diameter) according to actual output current. The torque at the Connector shall not exceed 8 Kgf.cm. (6.94 Ibf.in).
The insulation stripping length should not exceed 0.275" or 7 mm. (Refer to Fig. 3).
Installation of Mounting Accessories
All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
8
www.DeltaPSU.com (April 2023, Rev. 12)
assembly onto the mounting surface.
Base Mounting (Horizontal)
Fig. 3
Assembly Reference

Advertisement

Table of Contents
loading

Table of Contents