TECHNICAL DATASHEET
Sync DIN Rail Power Supply
12V 50W 1 Phase (NEC Class 2) / DRS-12V50W1N
*This picture is for reference to DRS-12V50W series only.
General Description
The ultra-compact and competitively priced Delta Sync DIN Rail DRS-12V50W1N☐ power supply is designed for industrial applications
requiring highly reliable power supply that must fit in a small space. The Sync series operates with universal AC input range and offers
full power up to 55°C. The output is adjustable from 12-15 volts, and can support up to 3000 microfarads of load capacitance. A green
LED indicates output is present. The design is certified according to IEC/EN/UL 60950-1 Information Technology Equipment (ITE) and
UL 508 Industrial Control Equipment (ICE). The series is also fully compliant with RoHS Directive 2011/65/EU for environmental
protection. NEC Class 2 and Limited Power Source (LPS) approvals are available for this product.
Model Information
Sync DIN Rail Power Supply
Model Number
DRS-12V50W1N☐
Model Numbering
DR
S –
DIN Rail
Product Series
S – Sync Series
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
1
www.DeltaPSU.com (March 2016, Rev. 00)
Input Voltage Range
85-264Vac (120-375Vdc)
12V
50W
Output Voltage
50W series
Highlights & Features
Ultra-compact size and galvanic isolation up to 3.0KVac
between input to output and input to ground
Universal AC input voltage and full power from -10°C to
+55°C operation
Up to 89.0% efficiency
Low earth leakage current < 0.5mA @ 264Vac
Built-in DC OK relay contact option available
Extreme low temperature cold start at -40°C
NEC Class 2 / Limited Power Source (LPS) certified
Safety Standards
CB Certified for worldwide use
Model Number:
Unit Weight:
Dimensions (L x W x D):
Rated Output Voltage
12Vdc
1
N
Single Phase
NEC Class 2
DRS-12V50W1N☐
0.18 kg (0.40 lb)
75 x 30 x 89.5 mm
(2.95 x 1.18 x 3.52 inch)
Rated Output Current
4A
Z – Without DC OK Relay
Contact
R – With DC OK Relay
Contact

Advertisement

loading

Summary of Contents for Delta Sync DRS-12V50W1N Series

  • Page 1 General Description The ultra-compact and competitively priced Delta Sync DIN Rail DRS-12V50W1N☐ power supply is designed for industrial applications requiring highly reliable power supply that must fit in a small space. The Sync series operates with universal AC input range and offers full power up to 55°C.
  • Page 2 TECHNICAL DATASHEET Sync DIN Rail Power Supply □ 12V 50W 1 Phase (NEC Class 2) / DRS-12V50W1N Specifications Input Ratings / Characteristics Nominal Input Voltage 100-240Vac Input Voltage Range 85-264Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz DC Input Voltage Range* 120-375Vdc Input Current <...
  • Page 3 TECHNICAL DATASHEET Sync DIN Rail Power Supply □ 12V 50W 1 Phase (NEC Class 2) / DRS-12V50W1N Mechanical Case Cover / Chassis Plastic Dimensions (L x W x D) 75 x 30 x 89.5 mm (2.95 x 1.18 x 3.52 inch) Unit Weight 0.18 kg (0.40 lb) Indicator...
  • Page 4 TECHNICAL DATASHEET Sync DIN Rail Power Supply □ 12V 50W 1 Phase (NEC Class 2) / DRS-12V50W1N Reliability Data MTBF Telcordia SR-332 > 700,000 hrs I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C MIL-HDBK-217F 230,000 hrs I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C Expected Cap Life Time 10 years (115ac &...
  • Page 5 TECHNICAL DATASHEET Sync DIN Rail Power Supply □ 12V 50W 1 Phase (NEC Class 2) / DRS-12V50W1N EMC / Emissions Generic Standards: EN 61000-6-3, EN 61000-6-4 CISPR 22, EN 55022 EN 55011, FCC Title 47: Class B Component Power Supply for General Use EN 61204-3 Immunity to Generic Standards: EN 55024, EN 61000-6-1, EN 61000-6-2...
  • Page 6 TECHNICAL DATASHEET Sync DIN Rail Power Supply □ 12V 50W 1 Phase (NEC Class 2) / DRS-12V50W1N Block Diagram DRS-12V50W1NZ DRS-12V50W1NR All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (March 2016, Rev. 00)
  • Page 7 TECHNICAL DATASHEET Sync DIN Rail Power Supply □ 12V 50W 1 Phase (NEC Class 2) / DRS-12V50W1N Device Description DRS-12V50W1NZ Input terminal block connector Output terminal block connector DC voltage adjustment potentiometer DC OK LED (Green) Universal mounting system DRS-12V50W1NR Input terminal block connector Output terminal block connector DC OK relay contact...
  • Page 8 TECHNICAL DATASHEET Sync DIN Rail Power Supply □ 12V 50W 1 Phase (NEC Class 2) / DRS-12V50W1N Dimensions L x W x D: 75 x 30 x 89.5 mm [2.95 x 1.18 x 3.52 inch] DRS-12V50W1NZ L x W x D: 75 x 30 x 89.5 mm [2.95 x 1.18 x 3.52 inch] DRS-12V50W1NR All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
  • Page 9 TECHNICAL DATASHEET Sync DIN Rail Power Supply □ 12V 50W 1 Phase (NEC Class 2) / DRS-12V50W1N Engineering Data Output Load De-rating VS Surrounding Air Temperature Note Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig.
  • Page 10 TECHNICAL DATASHEET Sync DIN Rail Power Supply □ 12V 50W 1 Phase (NEC Class 2) / DRS-12V50W1N Assembly & Installation The power supply unit (PSU) can be mounted on 35mm DIN rails in accordance with EN60715. The device should be installed with input terminal block at the bottom.
  • Page 11 TECHNICAL DATASHEET Sync DIN Rail Power Supply □ 12V 50W 1 Phase (NEC Class 2) / DRS-12V50W1N Functions ■ Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Start-up Time The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state set value.
  • Page 12 TECHNICAL DATASHEET Sync DIN Rail Power Supply □ 12V 50W 1 Phase (NEC Class 2) / DRS-12V50W1N Overload & Overcurrent Protections (Auto-Recovery) Overvoltage Protection (Latch Mode) The power supply’s Overload (OLP) and Overcurrent (OCP) The power supply’s overvoltage circuit will be activated when its Protections will be activated when output current is about 4.5A internal feedback circuit fails.
  • Page 13 Fig. 3 Parallel Operation Connection Diagram Others Delta RoHS Compliant Restriction of the usage of hazardous substances The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment.

This manual is also suitable for:

Sync drs-12v50w1nzSync drs-12v50w1nrSync drs-24v30w1az