Download Print this page
Delta PMT-V350W1A Series Instruction Manual
Delta PMT-V350W1A Series Instruction Manual

Delta PMT-V350W1A Series Instruction Manual

Advertisement

Quick Links

Instruction Manual
1.
Safety Instructions
Must select correct AC input voltage before turning on (Refer to Fig. 1).
The device is not recommended to be placed on low thermal conductive surface. For example,
plastics.
For safety reasons, please ensure the mounted device is kept at ≥ 4mm safety distance at all sides
from other components and equipments. In addition, to ensure sufficient convection cooling,
always maintain a distance of ≥ 20mm from fan ventilated surfaces while the device is in operation.
Please insert an insulation sheet between the system and product, if the safety distance is < 4mm
(Refer to Fig. 3).
Note that the enclosure of the device can become very hot depending on the ambient temperature
and load of the power supply. Do not touch the device while it is in operation or immediately after
power is turned OFF. Risk of burning!
Do not touch the terminals while power is being supplied. Risk of electric shock.
Prevent any foreign metal, particles or conductors from entering the device through the openings
during installation. It may cause: - Electric shock; Safety Hazard; Fire; Product failure.
Warning: When connecting the device, secure Earth connection before connecting L and N. When
disconnecting the device, remove L and N connections before removing the Earth connection. The
power supply must be mounted by metal screws onto a grounded metal surface. It is highly
recommended that the Earth terminal on the connector be connected to the grounded metal
surface.
2.
Device Descriptions
Refer to Fig. 1.:
1
Input & Output terminal block connector
2
DC voltage adjustment potentiometer
3
DC OK control LED (Green)
4
AC selectable switch
3.
Installation of the Device
A
Side Mounting: Fig. 2 and Fig. 3 show the mounting hole locations for power supply
assembly onto a metal mounting surface. The power supply shall be mounted on minimum of
4 mounting holes using M4 screw of maximum 5mm length (Refer to Fig. 5). This is to
maintain a safety distance between the screw and internal components.
B
Base Mounting: Fig. 2 and Fig. 3 show the mounting hole locations for power supply
assembly onto a metal mounting surface. The power supply shall be mounted on minimum of
4 mounting holes using M4 screw of maximum 4mm length (Refer to Fig. 5). This is to
maintain a safety distance between the screw and internal components.
C
Fig. 2: Connector
D
Fig. 2: This surface belongs to customer's end system or panel where the device is mounted.
Use flexible cable (stranded or solid) with the following sizes:
Output Voltage
4.2-5V
Wire Size
AWG 14-12
The input/output connectors' allowable current is 23A max per pin. User should calculate and
select the suitable wire specification (type/quantity/diameter) according to actual output current.
The torque at the connector shall not exceed 13Kgf.cm. The insulation stripping length should not
exceed 0.275" or 7mm (Refer to Fig. 4).
Recommended mounting torque of the product and its mounting accessories is 9~12Kgf.cm.
4.
Installation of Mounting Accessories
Please refer to the requirements in section 3 for the "Installation of the Device".
REV.07
All manuals and user guides at all-guides.com
12V
24V
36-48V
AWG 16-12
AWG 20-12
AWG 22-12
PMT-24V350W1AG, PMT-☐V350W1AK,
PMT-☐V350W1AN (Front Face Terminal Block)
Fig. 1. Device Descriptions
Base Mounting (Horizontal)
Base Mounting (Vertical)
Fig. 2. Mounting Orientations
Fig. 3. Mounting Hole Locations and the Safety Distance
Lug
Stripped wire
Fig. 4. Wire Type
PMT-☐V350W1A☐
PMT-☐V350W1AM, PMT-☐V350W1AR
(Standard Terminal Block)
Side Mounting (Horizontal)
Safety Distance
D1 = 4.0mm Min.
D2 = 20.0mm Min.
Fig. 5. Assembly Reference
www.DeltaPSU.com

Advertisement

loading

Summary of Contents for Delta PMT-V350W1A Series

  • Page 1 Instruction Manual All manuals and user guides at all-guides.com PMT-☐V350W1A☐ Safety Instructions PMT-24V350W1AG, PMT-☐V350W1AK, PMT-☐V350W1AM, PMT-☐V350W1AR • Must select correct AC input voltage before turning on (Refer to Fig. 1). PMT-☐V350W1AN (Front Face Terminal Block) (Standard Terminal Block) • The device is not recommended to be placed on low thermal conductive surface. For example, plastics.
  • Page 2 All manuals and user guides at all-guides.com PMT-☐V350W1A☐ 使用說明書 使用说明书 安全規範 安全规范 • • 通電前需選擇正確電壓 (依據圖一)。 通电前需选择正确电压 (依据图一)。 • 與風扇表面保持至少 20mm 的距離,以確保對流冷卻充分。 • 与风扇表面保持至少 20mm 的距离,以确保对流冷却充分。 • • 本產品不適合擺放在低熱導體,例如:塑膠。 本产品不适合摆放在低热导体,例如:塑胶。 • 本產品安裝完成後,周圍設備必須與本產品保持至少 4mm 的距離以滿足安全規範 (請參考 • 本产品安装完成后,周围设备必须与本产品保持至少 4mm 的距离以满足安全规范 (请参 圖三)。當距離無法達到...

This manual is also suitable for:

Pmt-v350w1ak seriesPmt-v350w1an seriesPmt-v350w1am seriesPmt-v350w1ar seriesPmt-24v350w1ag