2.2.2

LED Descriptions

Table 19
LED and Condition
LED
ALM
FIND ME
Note: Supported only on L100
Issue 14, FC95453R11-I14, and
later.
C1...C9
E1
·
Release 19.1.1
Issue 1.1, May 2021
Color
Yellow
Red
Off
Off
Blue
Off
Green
Red
Off
Green
Yellow
Red
Off
Condition
Minor alarm
Critical or major alarm
No alarm
No power
A CLI command has been used to activate this LED
Default state when powered on
Incoming optical signal operating normally
Input port down
One of the following alarms is present:
■ powerOutOfSpecificationHigh
■ powerOutOfSpecificationLow
Power off
Incoming optical signal operating normally
Payload Missing Indication (PMI)
High Reflection (HREF)
Backward Detect Indication-Optical Layer (BDI-O)
One of the following alarms is present:
■ postBlockSpanAdjustmentInProgress
■ preBlockSpanAdjustmentInProgress
WDM Loss of Signal (LOS)
WDM power out of specification
One of the following alarms is present:
■ omsLossOfSignal
■ omsPowerOutOfSpecificationHigh
■ omsPowerOutOfSpecificationLow
■ oscPowerOutOfSpecificationHigh
■ oscPowerOutOfSpecificationLow
■ otsLossOfSignal
■ otsSpanlossOutOfSpecificationHigh
■ otsSpanlossOutOfSpecificationLow