443
Equipment Removal
Remove Blade from Housing
PIU Slots
Fiber Restraint
Gate
Set Screw
Open
Closed
Figure 181
Unlatching Fiber Restraint Gate
Step 2
After opening the fiber restraint gates, carefully loosen the set screws on the left- and right-hand sides of the
blade, using a Phillips head screwdriver, to detach it from the Housing.
Note: The set screws are accessible after opening the fiber restraint gates on the left- and right-hand sides of
the blade.
Step 3
Close both fiber restraint gates after loosening the set screws and disengaging the blade from the Housing.
·