Autodrive ® 19 Tandem Description - Lincoln Electric AutoDrive 19 TANDEM Operator's Manual

Table of Contents

Advertisement

A-3
1. STATUS LED
The status light is a two color LED. Normal operation
is steady green. Flashing green or red/green indi-
cates a system error. See the troubleshooting sec-
tion.
Note: At power up of the Power Wave
tus light will flash green for up to 60 seconds.
This is normal and indicates that the system is
performing a self test and mapping each compo-
nent in the local ArcLink system. The status lights
will also flash green as a result of a system reset
or configuration change during operation. When
the status lights become steady green, the system
is ready for operation.
2. ARCLINK INPUT CONNECTOR (5 PIN):
Receives power and communication from the power
source
3. ARCLINK OUTPUT CONNECTOR (5 PIN):
Provides power and communication to the robotic
controller.
4. 14 PIN CONNECTOR:
Provides motor power, tach feedback, solenoid drive
and electrode sense (67) between the AutoDrive
controller and the wire feeder.
5. EXTERNAL I/O CONNECTOR:
Terminal Strip for making simple input signal connec-
tions. (See Figure A.2)
The terminal strip is divided into three groups:
Group #1 - TRIGGER
Group #2 - FEED FORWARD/REVERSE
Group #3 - SHUTDOWN INPUTS
INSTALLATION
AUTODRIVE
®
19 TANDEM DESCRIPTION
FIGURE A.1
®
system, the sta-
®
®
AutoDrive
5
4
1
When the Power Wave Power Source is controlled via
DeviceNet, the "TRIGGER" and "Feed" groups can
interfere with the welding sequence and should not be
used.
All inputs use "normally open" logic except the shut-
down group. The shutdown inputs use "normally
closed" logic, and are always enabled. Unused shut-
downs must be tied to the +15V supply for the shut-
down group. Machines are shipped from the factory
with jumpers installed on both shutdown inputs.
Shutdown 1 and shutdown 2 inuts are for weld system
faults and should not be used as emergency or safety
shutdowns.
12
11
10
9
19
SELECTING A WIRE DRIVE
AND GEAR RATIO
The AutoDrive
19 Tandem can accommodate a num-
®
ber of wire drives including the AutoDrive
AutoDrive
4R220 and Power Feed
®
control system must be configured for both the wire
drive and the gear ratio. This can be accomplished
with the Power Wave
available at www.powerwavesoftware.com.
®
19 Tandem
3
2
FIGURE A.2
2
6
3
8
7
5
4
10R. The feeder
®
Manager Utility. This utility is
®
A-3
1
4R100,
®

Advertisement

Table of Contents
loading

Table of Contents