To Connect The Domestic Hot Water Pump - Daikin EPRA18DAW1 Installer's Reference Manual

Hide thumbs Also See for EPRA18DAW1:
Table of Contents

Advertisement

8
|
Electrical installation

8.3.5 To connect the domestic hot water pump

Installer reference guide
98
A
B
A
B
3 Fix the cable with cable ties to the cable tie mountings.
Wires: (2+GND)×0.75 mm²
DHW pump output. Maximum load: 2 A (inrush), 230 V AC, 1 A
(continuous)
[9.2.2] DHW pump
[9.2.3] DHW pump schedule
1 Open the following (see
1 Top panel
2 User interface panel
3 Upper switch box cover
2 Connect the domestic hot water pump cable to the appropriate terminals as
shown in the illustration below.
S3S
S2S
3
4
5
6
3 4 5 6
"6.2.5 To open the indoor
EPRA14~18DAV3+W1 + ETVZ16S18+23DA6V+9W
X5M
4
unit" [
 50]):
Daikin Altherma 3 H HT F
4P587503-1A – 2020.01
1
3
2