Surveillance I/O Connector Functions - Toa SV-200M Instruction Manual

System management amplifier remote microphone
Table of Contents

Advertisement

22. SURVEILLANCE I/O CONNECTOR FUNCTIONS

The rear panel Surveillance I/O connector* permits "Speaker Line Reference Impedance Measurement (Initial
Setting)" and "Speaker Line Check" to be enabled and monitored by connected external equipment. Referring
to the pin arrangement and functions, prepare the matching D-sub male connector (screw-lock type) for
connection to the external equipment. (See p. 11 No. 41 SURVEILLANCE I/O connector.)
* Requires installation of the optional SV-200M Surveillance Board.
SV-200M's D-sub female connector
SURVEILLANCE I/O
13
25
SURVEILLANCE I/O connector pin function table
Pin
Signal name
No.
1
Zone 1 short
2
Zone 1 Disconnection
3
Zone 2 short
4
Zone 2 Disconnection
5
Zone 3 short
6
Zone 3 Disconnection
7
Zone 4 short
8
Zone 4 Disconnection
9
Zone 5 short
10
Zone 5 Disconnection
11
Ground fault
12
Power amplifier failure
13
Setting/checking busy
14
Initial setting error
15
I
22
23
Speaker line check
activation
24
Speaker line initial
setting activation
25
38
1
Locking nut: 4-40 UNC
14
IN
Signal/logic
/OUT
OUT
Active Low
OUT
Active Low
OUT
Active Low
OUT
Active Low
OUT
Active Low
OUT
Active Low
OUT
Active Low
OUT
Active Low
OUT
Active Low
OUT
Active Low
OUT
Active Low
OUT
Active Low
OUT
Active Low
OUT
Active Low
IN
One-shot make
IN
One-shot make
Function/status
Zone 1 speaker line is shorted.
Zone 1 speaker line is disconnected.
Zone 2 speaker line is shorted.
Zone 2 speaker line is disconnected.
Zone 3 speaker line is shorted.
Zone 3 speaker line is disconnected.
Zone 4 speaker line is shorted.
Zone 4 speaker line is disconnected.
Zone 5 speaker line is shorted.
Zone 5 speaker line is disconnected.
Some of speaker lines are grounded.
Power amplifier is faulty.
During measurement of the speaker line
reference impedance (Initial setting) or during
check of the speaker lines.
The speaker line reference impedance
couldn't be measured successfully.
(The measured impedance exceeds the
expected range or is unstable.)
Not used.
Check of the speaker line impedance starts.
Measurement of the speaker line reference
impedance (Initial setting) starts.
Not used.