VANTAGE 549
connection of wire feeDers with control
caBle (14 pin)
WARNING
Shut off welder before making any electrical connections.
CONNECTION OF LF-72, LF-74, FLEX FEED 74 HT,
FLEX FEED 84, LN-25 PRO DUAL POWER TO THE
VANTAGE® 549
• Shut the welder off.
• Set the "WIRE FEEDER VOLTMETER" switch to either "+" or
"-" as required by the electrode being used (See Figure A.5).
• For electrode Positive, connect the electrode cable to the "+"
terminal of the welder and work cable to the "-" terminal of
the welder. For electrode Negative, connect the electrode
cable "-" terminal of the welder and work cable to the "+"
terminal of the welder.
• Set the "MODE" switch to the "CV-WIRE" position.
• Adjust the "ARC CONTROL" knob to desired Crispness. SOFT
for MIG and CRISP for Innershield.
• Set the "WELDING TERMINALS" switch to the "REMOTELY
CONTROLLED" position.
• Set the wire feeder voltage switch to 42V.
• Connect the 14 pin control cable from the wire feeder to the
engine drive (See Figure A.6).
• Set the "REMOTE/LOCAL" switch to "REMOTE" if the feeder is
equipped with a remote output control knob.
ENGINE WELDER
Set Weld Terminals to
Set Mode to
CV Wire
Set to
42V
FIGURE A.6
K1797-xx
CABLE
A-9
INSTALLATION
FIGURE A.5
Remotely Controlled
Set Polarity to Match
Electrode Polarity
Set to
Remote