Rear Vent Configuration With Horizontal Termination (With Vertical Rise) - Lopi 564 GSR2 25K CF Installation Manual

Deluxe fireplace
Table of Contents

Advertisement

26
Finalizing the Installation

Rear Vent Configuration with Horizontal Termination (with vertical rise)

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Up to four elbows (45° or 90°) may be used.
Only one horizontal elbow may be used.
Use 8" diameter vent.
22' max (6.7 m)
20 feet (6 m)
15 feet (4.5 m)
10 feet (3 m)
5 feet (1.5 m)
0 feet
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
© Travis Industries
Exhaust Restrictor # 5
Intake Restrictor # 2
Diffuser Position # 2
Exhaust Restrictor # 4
Intake Restrictor # 2
Diffuser Position # 2
Exhaust Restrictor # 1 (stock)
Intake Restrictor # 1 (stock)
Diffuser Position # 1 (stock)
- Remove the Exhaust Restrictor
and Install Exhaust Deflector
- Intake Restrictor # 1 (stock)
- Diffuser Position # 1 (stock)
H2
H1
5/15/2019 - 1508
(for qualified installers only)
Exhaust Restrictor # 2
10 feet (3 m)
Intake Restrictor # 1 (stock)
Diffuser Position # 1 (stock)
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is considered a
vertical elbow
564 GSR2 25K CF (AUST)
22' max (6.7 m)
20 feet (6 m)
15 feet (4.5 m)
5 feet (1.5 m)
0 feet

Advertisement

Table of Contents
loading

Table of Contents