Finalizing the Installation

Top Vent Configuration with Horizontal Termination

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Up to four elbows (45° or 90°) may be used.
Use 8" vent.
Only one horizontal elbow may be used.
21' max (6.4m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
© Travis Industries
Exhaust Restrictor # 5
Intake Restrictor # 2
Diffuser Position # 2
Exhaust Restrictor # 4
Intake Restrictor # 2
Diffuser Position # 2
Exhaust Restrictor # 1
Intake Restrictor # 1
Diffuser Position # 1
NOTE: If using an elbow with no vertical sections:
- Remove the Exhaust Restrictor (leave screws in place)
- Intake Restrictor # 1 (stock)
- Diffuser Position # 1 (stock)
H2
H1
5/15/2019 - 1508
(for qualified installers only)
Exhaust Restrictor # 2
Intake Restrictor # 1
Diffuser Position # 1
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is considered a
vertical elbow
564 GSR2 25K CF (AUST)
21' max (6.4m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet