Quick Wizard: Capacities (Energy Metering); Space Heating/Cooling Control - Daikin Altherma EDLQ05CAV3 Installation Manual

Hide thumbs Also See for Altherma EDLQ05CAV3:
Table of Contents

Advertisement

5 Configuration
#
Code
[A.2.2.E.5]
[C-05]
External room thermostat for the main
zone:
▪ 1 (Thermo ON/OFF): When the used
external
heat pump convector can only send a
thermo
separation
cooling demand.
▪ 2 (H/C request): When the used
external room thermostat can send a
separate heating/cooling thermo ON/
OFF condition.
If there are two zones (main
+additional), then only Thermo ON/OFF
is possible.
[A.2.2.E.6]
[C-06]
External room thermostat for the
additional zone:
▪ 0: N/A
▪ 1 (Thermo ON/OFF): When the used
external
heat pump convector can only send a
thermo
separation
cooling demand.
▪ 2: N/A
If there are two zones (main
+additional), then only Thermo ON/OFF
is possible.
Option box EK2CB07CAV3
#
Code
[A.2.2.F.1]
[C-02]
External backup heater source:
▪ 0 (No): None
▪ 1 (Bivalent): Gas boiler , oil boiler
▪ 2: N/A
▪ 3: N/A
[A.2.2.F.2]
[C-09]
Alarm output
▪ 0 (Normally open): The alarm output
will be powered when an alarm
occurs.
▪ 1 (Normally closed): The alarm
output will NOT be powered when an
alarm occurs. This installer setting
allows for a distinction between the
detection of an alarm, and the
detection of a power failure.
See also table below (Alarm output
logic).
[A.2.2.F.3]
[D-08]
Optional external kWh meter 1:
▪ 0 (No): NOT installed
▪ 1: Installed (0.1 pulse/kWh)
▪ 2: Installed (1 pulse/kWh)
▪ 3: Installed (10 pulse/kWh)
▪ 4: Installed (100 pulse/kWh)
▪ 5: Installed (1000 pulse/kWh)
Installation manual
14
Description
room
thermostat
or
ON/OFF
condition.
No
between
heating
or
room
thermostat
or
ON/OFF
condition.
No
between
heating
or
Description
#
Code
[A.2.2.F.4]
[D-09]
Optional external kWh meter 2:
▪ 0 (No): NOT installed
▪ 1: Installed (0.1 pulse/kWh)
▪ 2: Installed (1 pulse/kWh)
▪ 3: Installed (10 pulse/kWh)
▪ 4: Installed (100 pulse/kWh)
▪ 5: Installed (1000 pulse/kWh)
#
Code
[A.2.2.F.5]
[C-08]
External sensor (indoor):
▪ 0 (No): NOT installed.
▪ 1 (Outdoor sensor): Remote outdoor
sensor, connected to the outdoor
unit.
▪ 2 (Room sensor): Remote indoor
sensor, connected to option box
EK2CB07CAV3.
INFORMATION
You can only connect either the remote indoor sensor or
the remote outdoor sensor.
#
Code
[A.2.2.F.6]
[D-04]
PCC by digital inputs:
▪ 0 (No)
▪ 1 (Yes)
5.2.4
Quick wizard: Capacities (energy
metering)
#
Code
[A.2.3.1]
[6-02]
Booster heater capacity [kW]
[A.2.3.2]
[6-03]
Backup heater capacity (step 1) [kW]
[A.2.3.3]
[6-04]
Backup heater capacity (step 2) [kW]
5.2.5

Space heating/cooling control

Leaving water temperature: Main zone
#
Code
[A.3.1.1.1]
N/A
Set point mode:
▪ 0 (Fixed): Absolute
▪ 1
dependent
▪ 2
scheduled (only for leaving water
temperature control)
▪ 3
dependent + scheduled (only for
leaving water temperature control)
Daikin Altherma low temperature monobloc
Description
Description
Description
Description
Description
(Weather
dep.):
Weather-
(Fixed/scheduled):
Absolute
(WD/scheduled):
Weather-
EBLQ+EDLQ05+07CAV3
4P403578-1C – 2016.02
+

Advertisement

Table of Contents
loading

Table of Contents