Quick Wizard: Capacities (Energy Metering); Space Heating/Cooling Control - Daikin Altherma EHVH08S18CB Installation Manual

Low temperature split
Hide thumbs Also See for Altherma EHVH08S18CB:
Table of Contents

Advertisement

#
Code
[A.2.2.6.2]
[D-07]
Solar pump station kit:
▪ 0 (No): NOT installed
▪ 1 (Yes): Installed
[A.2.2.6.3]
[C-09]
Alarm output on optional EKRP1HB
PCB:
▪ 0 (Normally open): The alarm output
will be powered when an alarm
occurs. By setting this value, a
distinction is made between the
detection of an alarm, and the
detection of a power failure.
▪ 1 (Normally closed): The alarm
output will NOT be powered when an
alarm occurs.
See also table below (Alarm output
logic).
[A.2.2.6.4]
[F-04]
Bottom plate heater
▪ 0 (No): NOT installed
▪ 1 (Yes): Installed
Alarm output logic
[C-09]
Alarm
0 (default)
Closed output
1
Open output
Demand PCB
#
Code
[A.2.2.7]
[D-04]
Demand PCB
Only applicable for EHBH/X04+08 and
EHVH/X04+08. Indicates if the optional
demand PCB is installed.
▪ 0 (No)
▪ 1 (Pwr consmp ctrl)
Energy metering
#
Code
[A.2.2.8]
[D‑08]
Optional external kWh meter 1:
▪ 0 (No): NOT installed
▪ 1: Installed (0.1 pulse/kWh)
▪ 2: Installed (1 pulse/kWh)
▪ 3: Installed (10 pulse/kWh)
▪ 4: Installed (100 pulse/kWh)
▪ 5: Installed (1000 pulse/kWh)
[A.2.2.9]
[D‑09]
Optional external kWh meter 2:
▪ 0 (No): NOT installed
▪ 1: Installed (0.1 pulse/kWh)
▪ 2: Installed (1 pulse/kWh)
▪ 3: Installed (10 pulse/kWh)
▪ 4: Installed (100 pulse/kWh)
▪ 5: Installed (1000 pulse/kWh)
5.2.4
Quick wizard: Capacities (energy
metering)
#
Code
[A.2.3.1]
[6-02]
Booster heater capacity [kW]
EHVH/X04~16S18CB + EHVH/X08~16S26CB
Daikin Altherma – Low temperature split
4P384971-1E – 2018.02
Description
No alarm
No power
supply to unit
Open output
Open output
Closed output
Description
Description
Description
#
Code
[A.2.3.6]
[6-07]
Bottom plate heater capacity [W]
5.2.5

Space heating/cooling control

Leaving water temperature: Main zone
#
Code
[A.3.1.1.1]
N/A
Set point mode:
▪ 0 (Fixed): Absolute
▪ 1
dependent
▪ 2
scheduled (only for leaving water
temperature control)
▪ 3
dependent + scheduled (only for
leaving water temperature control)
[7.7.1.1]
[1-00]
Weather-dependent curve (heating):
T t
[1-01]
[1-02]
[1-02]
[1-03]
[1-03]
▪ T
(main)
▪ T
[7.7.1.2]
[1-06]
Weather-dependent curve (cooling):
T t
[1-07]
[1‑08]
[1-08]
[1-09]
[1-09]
▪ T
(main)
▪ T
Leaving water temperature: Additional zone
#
Code
[A.3.1.2.1]
N/A
Set point mode:
▪ 0 (Fixed): Absolute
▪ 1
dependent
▪ 2
scheduled (only for leaving water
temperature control)
▪ 3
dependent + scheduled (only for
leaving water temperature control)
5 Configuration
Description
Description
(Weather
dep.):
Weather-
(Fixed/scheduled):
Absolute
(WD/scheduled):
Weather-
[1-00]
[1-01]
: Target leaving water temperature
t
: Outdoor temperature
a
[1-06]
[1-07]
: Target leaving water temperature
t
: Outdoor temperature
a
Description
(Weather
dep.):
Weather-
(Fixed/scheduled):
Absolute
(WD/scheduled):
Weather-
Installation manual
+
T a
T a
+
15

Advertisement

Table of Contents
loading

Table of Contents