Daikin Altherma EDLQ05CAV3 Installation Manual page 25

Hide thumbs Also See for Altherma EDLQ05CAV3:
Table of Contents

Advertisement

Control box
X3M/1
X3M/2
X3M/3
X3M/4
X5Y
X5M/4
X5M/3
X5M/2
Hydro switch box
X5M/1
A5P
Remote
A5P
Q5DI
user interface
User interface
R1T
R1T
-t°
-t°
P1P2
P1P2
X2M
20
21
1N~, 50 Hz
230 V AC
L
N PE
Q6DI
2
4
X8M
F2B
I
I
1
3
2
4
A2
K3M
A1
1
3
X4M
1
2
X6M/X9M
X6M/X9M
1
2
1/3/31
Q2L/Q3L
Q2L
2/4/32
E4H
domestic hot water tank
domestic hot water tank
7
only for
only for
*KHW(E/S)*V3
*KHW(E/S)*Z2
DHW option
Control box option: backup heater
R2T
X15M
- t°
1
X2M : 5
X2M : 6
2
X15M
3
X2M : 12
4
X2M : 11
5
X2M : 13
6
X2M : 14
7
X2M : 15
Control box
F1U
K1R
1
3
4
5
A1
A2
K1M
2
BUH option (only for *3V)
EBLQ+EDLQ05+07CAV3
Daikin Altherma low temperature monobloc
4P403578-1C – 2016.02
DHW pump output
Max. load:
2 A (inrush) - 230 V AC
1 A (continuous)
1N~, 50 Hz
L N
230 V AC
DHW pump
M2P
Option box
M
1~
X1M/L
X1M/N
X1M/PE
X2M
23
22
X1M
L N
1
K1A
5
1
K2A
5
X10A
X1A
2 1
5
4
3
F1U
F1U
2
1
X2A
5
F2U
4
1
3
2
2
3
1
K1
1
2
L1
N
11/1
21/3
STB
12/2
22/4
E4H
K2
domestic hot water tank
7
only for
*KHWP*/*HYC*
1N~, 50 Hz
R2T
230 V AC
X15M
- t°
L
N
1
2
X15M
Q1DI
3
4
5
6
2
4
7
F1B
I
I
1
3
K1R
Q1L
K2R
31
11
21
1
32
12
22
5
2
4
1
3
E3H
F1T
2
BUH option (*9W)
Heatpump convector
3
NO valve
M2S
5
only for wired On/OFF
thermostat
M4S
L
N
Y
5
X8M
10
9
8
7
6
2a
4
3
X3A
8
+12V
DS1
ON
OFF
8 7 6 5 4 3 2 1
GND
1 2 3 4 5 6
X4A
X2M
7 8 9 10
Control
box
X9M
1314
Q2L
M3S
21/31
Y
N
22/32
L
8
7
only for
Only for
*KHWE*
*KHWS*
L1 L2 L3
Q1DI
F1U
2
4
31
11
Q1L
F1B
32
12
I
I
1
3
1
3
4
5
A1
2
4
K5M
1
3
A2
3
2
4
A1
4
K1M
1
3
A2
A1
K2M
A2
F1T
F1T
E1H E1H E1H
X14M
1
2 3
3
3N ~ 400 V 6 kW or 9 kW
8 Technical data
only for wireless On/OFF thermostat
only for ext. sensor
(floor or ambient)
X11M
4
5 6
%H20
A3P
R1T
R1H
-t°
X1M
A3P
Dual setpoint application
(refer to installation
PC
manual)
R1T
L N
C
H
COM
-t°
C
H
COM
A7P
A3P
5
R5T / X2M.4
R5T / X2M.3
X2M
1a 2 1
4
3
X2M
4
5
6
3
A4P
X5A
Option box
1
7
6
5
4 3 2 1
2
3
X2M
X14A
13
1
14
2
15
3
X2M
11
12
R5T
Q2L/
S1S
- t°
Q3L
Preferential kWh
3
rate power supply
contact:
4
5V DC detection
(voltage supplied
8
8
by PCB)
Only for
*KHWP*/*HYC*
4D094176-1C_Page 8
PE
N
L
N
Q1DI
6
8
4
6
2
F1B
I
I
I
I
I
5
7
1
3
5
6
14
2
4
6
K5M
5
13
1
3
5
6
K1M
2
4
6
5
5
1
3
2
4
6
K2M
1
3
5
F1T
F1T
F1T
F1T
F2T
F2T
F2T
E1H E1H E1H
E2H E2H E2H
4
5 6
X14M
1 2 3 4 5 6
3
1N~ , 230 V , 3 kW or 6 kW
4D094176-1C_Page 9
Installation manual
R2T
-t°
5
X15M : 1
X15M : 2
A4P/X5A.1
A4P/X5A.2
A4P/X5A.3
X15M : 5
X15M : 6
X15M : 7
X15M : 3
X15M : 4
BUH option
PE
8
I
7
14
13
2
4
6
1
3
5
F2T
F2T
F2T
E2H E2H E2H
25