en | Programming
4

Programming

Programming occurs via a PC or laptop connected to the fire panel with FSP-5000-RPS
(Remote Programming System) for panels with LSN improved version line technology
AVENAR detector 4000 is programmed by entering the area of operation. The selection of the
area of operation determines the optimum characteristic field for fire and disturbance variable
evaluation.
The operating mode can be changed for FAP-425-OT-R|FAP-425-OT, as well as for FAP-425-
DOTC-R|FAP-425-DOTCO-R and FAP-425-DOT-R, i.e. individual sensors can be switched off:
In the case of the purely optical FAP-425-O-R|FAP-425-O and FAP-425-DO-R detectors, the
sensitivity of the optical sensor can be set to three levels. Depending on the operating
location, the optical sensor in the detector is thus adjusted to the environmental conditions.
Notice!
For fire detection, the purely optical detector also evaluates the time behavior of the fire
i
characteristics, which differs significantly from the time behavior of disturbance variables and
that occurring during a detector test
As a result, there are also different trigger times when testing with a test aerosol outside of
Walk test operation (10 s to max 60 s), depending on the selected sensitivity adjustment.
FAH-425-T-R is programmed by taking into account the ambient temperature, the installation
height and the category as per EN 54 Part 5.
Programming of the optical, thermal, and chemical sensors and the linking of all sensors via
algorithms significantly increases the detection ability and security against false alarms.
4.1

FAP-425-DOTC-R and FAP-425-DOTCO-R

Notice!
i
The default setting of FAP-425-DOTC-R and FAP-425-DOTCO-R in FSP-5000-RPS is Hotel
room/smoker room.
Installation location
Office after hours
Hotel room/smoker room
= default setting
Office day mode
Server room
Production location
Garage
2023-06 | 07 | F.01U.283.550
Switch to optical (O sensor sensitivity = low, T sensor = switched off)
Switch to thermal differential (T sensor sensitivity = A2R, O sensor = switched off)
Switch to thermal maximum (T sensor sensitivity = A2S, O sensor = switched off).
Detector type Sensitivity
Temperature
(T)
O, T
, T
, C High (A2R)
max
diff
O, T
, T
, C High (A2R)
max
diff
O, T
, T
, C Low (BR)
max
diff
O, T
, T
, C High (A2R)
max
diff
O, T
, T
, C Low (BR)
max
diff
O, T
, T
, C High (A2R)
max
diff
Optical (O)
High
Low*
Medium
High
Low*
Low*
User manual
AVENAR detector 4000
Standard
Chemical (C)
High
EN 54-5, EN 54-7,
EN 54-29
Low
EN 54-5, EN 54-7
High
EN 54-5, EN 54-7,
EN 54-29
High
EN 54-5, EN 54-7,
EN 54-29
Medium
EN 54-5, EN 54-7
Low
EN 54-5, EN 54-7
Bosch Sicherheitssysteme GmbH

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents