Network Control Module 300 Series Technical Bulletin
Table 3: N1 LAN Cards
Card
Description
ARCNET
ARCNET LAN communication is provided by a standard ARCNET card (Ordered separately.
Card
See Specifications and Order Codes for more information.) connected into ISA Bus Slot 1
(Figure 1: Callout 4).
Ethernet
An Ethernet card (Ordered separately. See Specifications and Order Codes for more
Card
information.) connected into ISA Bus Slot 1 (Figure 1: Callout 4) of the NCM350 allows you to
connect the Metasys system directly to an Ethernet network. This allows you to communicate
with other devices on the Ethernet LAN, without the use of an Ethernet Router. Metasys
system functionality is the same on both the Ethernet and ARCNET LANs.
Note:
to have both ARCNET and Ethernet connections, you must use the ARCNET LAN and
connect to Ethernet using the Ethernet Router. For details, refer to the Metasys Ethernet
Router Technical Bulletin (LIT-6295035).
You cannot do smoke control on an Ethernet network where UL 864 is required. See the
Smoke Control Restrictions section of the Smoke Control Technical Bulletin (LIT-636330).
L
W
The L
ON
ORKS
ON
Network
L
W
ON
ORKS
NU-NET201-0
NU-NET202-0
NU-NET203-0
software) (LON-FTT10)
NU-NET203-1
software) (LON-FTT10)
The L
ON
The L
ON
L
W
ON
ORKS
are transferred across the network include:
commands from the NCM to the devices
automatic reporting of alarms and change-of-logic states from the DX-912x to the NCM (N2E
Bus only)
responses from the devices to the NCM, including identification and requested data values
complete databases for the DX-912x controllers (N2E Bus only)
time synchronization message from the NCM
analog and binary point data shared between devices
To meet FCC and CE standards for the N2E Bus installation, install ferrite clamps and beads.
For detailed information, refer to the L
Media
The Media Interface Board (MIB-OWS) is a communication card that allows the Fire-Net
Interface
NCM to be connected to the Metasys Intelligent Fire Network. Insert the MIB-OWS in the
Board
second ISA slot (Figure 1: Callout 5). Detailed information on setting up the NCM as a
Fire-Net NCM can be found in Appendix A: Fire-Net NCM of this document.
Serial Card
A non PnP serial card can be placed in either ISA slot to allow direct connection of a printer
or OWS. See Table 11 for details.
Note:
serial card. The serial card must use a 16550AF UART or equivalent. An example of a
16550AF serial card is the SIIG Model IO-1809. The card cannot be a PnP device.
You can use either an Ethernet or an ARCNET card in a single NCM350. If you wish
W
network allows communication between the Metasys network and
ORKS
compatible devices using the L
DX-9120 controllers on N2E Bus (N2E-TP78)
DX-9121 controllers on N2E Bus (N2E-FTT10)
L
W
compatible devices (requires Metasys Release 10.0 or later
ON
ORKS
L
W
compatible devices (requires Metasys Release 11.00 or later
ON
ORKS
W
interface card must be inserted in Slot 2 (Figure 1, Callout 5) of the NCM.
ORKS
W
network carries all communication between the NCM and the DX-912x or
ORKS
compatible devices and between the devices themselves. The types of data that
The serial card for Port 5 or Port 6 must be a 16-character FIFO (First-In, First-Out)
Internal modems are not recommended for use with NCM300s unless
the PnP feature can be disabled. Most new internal modems are PnP,
which is not compatible with NCM300s.
W
compatible interface cards as follows:
ON
ORKS
W
N2E Bus Technical Bulletin (LIT-6364100).
ON
ORKS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ncm300Ncm311Ncm350Ncm350-8Ncm361Ncm361-8

Table of Contents