Hoshizaki IM-50BAA-LM Service Manual page 30

Self-contained cuber
Hide thumbs Also See for IM-50BAA-LM:
Table of Contents

Advertisement

Control Board (CB) Setting Menu
Category No. Item
Other
20 Display Switching in Operation
Switches 7-segment display during operation.
"0": Display constantly shows "on".
"1": Display shows "on" for 3 min just after power
supply is turned on and then shows bar such as "_ _"
based on operational status.
SETTING CHANGE IS INEFFECTIVE.
21 Stackable Bin Control
Allows for stacked units to be controlled through one
bin
control.
DO NOT ADJUST
22 Refrigeration Circuit Cycling when Bin Full
Selection of control to prevent ice in storage bin from
melting in bin control cycle (by operating refrigeration
unit).
SETTING CHANGE IS INEFFECTIVE.
Fan Motor 30 Type
Selection of fan motor type. When set to "0", unit
operates as water-cooled model.
31 Target Rotation Speed
Normal fan motor rotation speed set with the first two
digits for 4-digit numbers and the first digit for 3-digit
numbers.
e.g. 1600 r/min = "16", 800 r/min = "8"
32 Low Speed Rotation Temperature
Condition to decrease target fan motor rotation
speed. When ambient temperature reaches down
to low speed rotation temperature (CB Setting 32),
target rotation speed is decreased by low speed
rotation rate (CB Setting 33).
33 Low Speed Rotation Rate
Percentage against target rotation speed (CB Setting
31).
34 High Speed Rotation Temperature
Condition to increase target fan motor rotation speed.
When ambient temperature reaches up to high speed
rotation temperature (CB Setting 34), target rotation
speed is increased by high speed rotation rate (CB
Setting 35).
35 High Speed Rotation Rate
Percentage against target rotation speed (CB Setting
31).
Range
0="on"
constantly
displayed
1=bar displayed
Yes=1; No=0
On=1; Off=0
0=water-cooled
1=small /
medium
2=large
4=new small
3 to 20 (x 100
rotations)
(1 increments)
10 to 45°C
(1°C increments)
20 to 100%
(00=100)
(1% increments)
50 to 60°C
(1°C increments)
100 to 120%
(00 to 20
displayed)
(1% increments)
29
Default
Default
(50BAA-Q)
(50BAA-LM)
0
0
1
1
0
0
4
4
14
15
25
26
100
30
60
60
100
100

Advertisement

Table of Contents
loading

This manual is also suitable for:

Im-50baa-q