Test Run; Converting Instructions - Electrolux Compass Pro TD6-10 Installation Manual

Hide thumbs Also See for Compass Pro TD6-10:
Table of Contents

Advertisement

24
Town gas
Gas category
1a
1b

7.5 Test run

• Loosen the measuring branch screw (2) 1/4 turn; connect a manometer to the measuring branch.
• Select a program with heat.
• Start the machine.
• Check the nozzle pressure, see "Table of pressure and adjustment".
• If necessary adjust the regulator setting screw (4) behind the cover screw (3). Replace the cover screw (3) if
removed.
• Check that the gas is burning evenly. The blue flame on the burner is preferred.
Note!
After connection all joints must be checked. There must not be any leaks.

7.6 Converting instructions

• Disconnect the power to the machine.
• Demount the back panel.
• Remove the nozzle (1).
• Mount the new supplied nozzle.
Installation manual
Inlet pressure
Nozzle pres-
(mbar)
sure (mbar)
8
4.5
8
3.5
1
Nozzle size (⌀
Air reducing/
mm)
restriction plate
(mm)
4.45
487042240
4.45
487042240
Label number
May be avail-
able in follow-
ing countries
Default
DK, IT
490376103
SE
fig.7120
fig.7506A