To Open The Indoor Unit - Daikin ETVZ16S18EA6V Installer's Reference Manual

Hide thumbs Also See for ETVZ16S18EA6V:
Table of Contents

Advertisement

7.2.5 To open the indoor unit

EPRA14~18DAV3+W1 + ETVZ16S18+23EA6V+9W
Daikin Altherma 3 H HT F
4P644739-1 – 2021.02
3 2
Overview
a
c
e
b
d
a Top panel
b User interface panel
c Switch box cover
d Front panel
e High voltage switch box cover
Open
1 Remove the top panel.
T25
2 Remove the user interface panel. Open the hinges at the top and slide the top
panel upwards.
NOTICE
If you remove the user interface panel, also disconnect the cables from the back of
the user interface panel to prevent damage.
7
4
1
3
2
4
1
Unit installation
|
Installer reference guide
55

Advertisement

Table of Contents
loading

Table of Contents