check the following items during installation prior to lighting
the multisided burner:
Check all carryover ports for blockage from the ceramic
media
o
If there is blockage, use a small pointed tool to move the
ceramic media away from the carryover port.
Check air shutter for correct setting.
o
Natural Gas – Air shutter 5/16" (7.93 mm) minimum open
o
Propane Gas – Air shutter full open
Page 22

BURNER INSTRUCTIONS

AIR SHUTTER
5/16" (7.93mm) OPEN
AIR SHUTTER
FULL OPEN
For best results when lighting the burner, have your adjustable
flame knob to the HI position, then adjust to a lower setting
after the burner has ignited.
When first lighting the pilot on the burner, it takes approximately
60 to 75 seconds to fully heat and energize the thermopile.
Once the thermopile is energized, turn on the gas valve and
light the burner.