Troubleshooting Guide - England's Stove Works 25-CAB80 Installation & Operation Manual

Table of Contents

Advertisement

WARNING: To avoid ELECTRICAL SHOCK always disconnect the unit from the power source BEFORE  
attempting any repair.  If this guide does not correct the problem, call Technical 
*See ERROR CODES section earlier in this manual for information on troubleshooting Error Codes 
Problem 
Top Auger not turning 
  
  
 
Bottom Auger not turning 
 
Smoke smell or dust in 
house 
Room blower not operating 
  
  
Exhaust blower not 
operating 
  
  
Lazy Fire 
  
  
  
Blown Fuse 
  
  
High Pellet Consumption 
Squeaking Noise 
  
Pinging or Rattling Noise 
  
IMPORTANT!  READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND 
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR 
 
 
Trouble‐Shooting Guide 
Support at 1‐800‐245‐6489. 
Cause  
1. Bad auger motor. 
2. Foreign matter jamming auger. 
3. Vacuum sensor. 
4.Hopper lid switch 
1. Bad auger motor. 
2. Foreign matter jamming auger. 
1. Improper exhaust connection. 
1. Loose thermal sensor. 
2. Blower speed set higher than heat 
range, causing stove to cool and 
blower to cycle. 
3. Loose connection. 
1. Loose connection. 
2. Bad blower. 
3. Bad vacuum sensor. 
1. Bad exhaust blower. 
2. Excessive pellet moisture. 
3. Excessive ash build‐up. 
4. Low quality pellets. 
1. Power surge. 
2. Exposed wire. 
3. Electrical component shorting. 
1. Low quality or non‐uniformly sized 
pellets. 
1. Obstruction in auger tube. 
2. Blower Noise. 
1. Foreign material in blower. 
2. Loose exhaust fan set screw. 
REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED. 
USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS. 
1. Replace auger motor. 
2. Remove pellets and object. 
3. Check exhaust blower. 
4.Make sure hopper lid is closed/replace 
switch 
1. Replace auger motor. 
2. Remove pellets and object. 
1. Check exhaust connections for leaks, 
especially the exhaust blower connect.  Seal 
leaks with silicone, aluminum tape or a hose 
clamp. 
1. Tighten connection on sensor. 
2. Lower blower speed. 
3. Check control board connection. 
1. Check control board connection. 
2. Replace blower. 
3. Replace vacuum sensor. 
1. Inspect and replace blower. 
2. Keep pellets dry. 
3. Thoroughly clean unit. 
4. Use only PFI premium pellets. 
1. Replace fuse; use surge protector. 
2. Check for exposed or frayed wire and loose 
connections. 
3. Check motors and blowers for obstructions 
or short circuits. 
1. Use premium pellets or try another pellet 
brand. 
1. Check auger tube for foreign objects. 
2. Remove, clean, and oil blower. 
1. Check both blowers for material. 
2. Check set screw for tightness. 