Manual/Automatic Mode - England's Stove Works 25-CAB80 Installation & Operation Manual

Table of Contents

Advertisement

CONTROL BOARD SETTINGS – TOP MOUNT BOARD 
 
Please Note: The following section gives instructions for stove models with the Top 
Mount control board (where the control board is mounted on the top of the stove, 
behind the hopper).  
Please see the section of the manual "Control Board Settings – Side Mount Board" 
for instructions pertaining to stoves with a Side Mount control board. 
Manual/Automatic Mode 
 
Automatic Mode 
Your  stove  will  arrive  from  the  factory  programmed  in  automatic  mode.  First,  make  sure  the  thermocouple 
wire is resting loosely outside the back of the stove (so that it is reading the air temperature) in a safe location 
where it can't be damaged. It should not rest directly on the floor, or it will pick up the floor temperature. The 
thermocouple  wire  is  the  "room  temperature  heat  sensor"  whereby  the  control  board  will  read  the  room 
temperature.  
In this mode, after initiating the startup sequence, you select the desired room temperature (ranging from 60 
to 90 degrees F) by pressing the Up or Down arrows, and the stove will operate the auger feed and blower 
speed according to the temperature you have selected.  
  
The stove will heat to whichever temperature you set the stove at until the call for heat leaves, at which point 
the stove will adjust itself higher or lower as needed, depending on the room temperature readings supplied 
by the room heat sensor. 
To turn the stove off completely, press the OFF button on the control board. 
Manual Mode 
Your stove can be changed to run in manual mode, if desired. In manual mode, after pressing the ON button, 
the  stove  will  run  continuously,  based  on  desired  heat  range  and  blower  speed  settings.  The  heat  range 
settings will be 1 through 9 (the Up arrow will increase the heat range and the Down arrow will decrease the 
heat range), with 1 being the lowest auger feed setting and 9 being the highest. The blower speed range will 
match the heat range that you have set.  
 Since the stove runs continuously at the selected heat range in this mode, it is generally recommended for 
stoves installed in less‐insulated areas of the home and extremely cold climate regions.  
To turn the stove off completely, press the OFF button on the control board. 
 
21 
IMPORTANT!  READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND 
REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED. 
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR 
USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS. 
 
 