1 Verify your emulation probe is now active and on the network by
2 To view the LAN parameters, enter the lan command at the terminal
3 To exit from this telnet session, type Ctrl+D at the prompt.
If You Have Problems "Problems with the LAN Interface" on page 145.
Connecting the Emulation Probe to a LAN
Verifying LAN Communications
To verify LAN communications using telnet
issuing a telnet to the IP address.
This connection will give you access to the emulation probe's built-in terminal
interface.
interface prompt.
The best way to change the emulation probe's IP address, once it has already
been set, is to telnet to the emulation probe and use the terminal interface lan
command to make the change. Remember, after making your changes, you
must cycle power before the changes take effect. Doing this will break the
connection and end the telnet session.
To use telnet on a 16700-series logic analysis system, select the System
Administration icon, select the Networking tab, then select telnet....
Example
$ telnet 192.35.12.6
R>lan
lan is enabled
lan -i 192.35.12.6
lan -g 0.0.0.0
lan -s 255.255.248.0
lan -p 6470
Ethernet Address : 08000F090B30
40