Agilent 16962A Logic Analyzer-At A Glance - Agilent Technologies 16962A Service Manual

Logic analyzer
Table of Contents

Advertisement

Agilent 16962A Logic Analyzer—At a Glance
4
The 16962A logic analyzer module is for the 16901A or
16902B logic analysis system frames. It provides 2 GT/s state
logic analysis and up to 8 GHz timing analysis. The 16962A
has 4 M to 100 M sample memory depth (depending on the
option chosen).
The 16962A logic analyzer module offers high performance
measurement capability.
Features
Some of the main features of the 16962A are as follows:
• 68 data channels, including:
2 clock/data channels.
2 clock ready/data channels.
• 2 GT/s maximum state acquisition speed.
• "Eye scan" feature.
• 2 GHz timing analysis on all channels at full memory
depth, 4 GHz timing analysis with 1/2 channels, and
8 GHz timing analysis with 1/4 channels.
• Expandable to 340 channels (5- card set).
Service Strategy
The service strategy for this instrument is the replacement
of defective assemblies. This service guide contains
information for finding a defective assembly by testing and
servicing the 16962A logic analyzer module.
The modules can be returned to Agilent Technologies for all
service work, including troubleshooting. Contact your nearest
Agilent Technologies Sales Office for more details.
Contacting Agilent Technologies
To locate a sales or service office near you, go to
www.agilent.com/find/contactus.
16962A Logic Analyzer Service Guide