Agilent 16089E Kelvin Clip Leads
Operation Note
Agilent Part No. 16089-90001
Printed in JAP AN
May 2000

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies 16089E

  • Page 1 Agilent 16089E Kelvin Clip Leads Operation Note Agilent Part No. 16089-90001 Printed in JAP AN May 2000...
  • Page 2 This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of the Agilent Technologies. Agilent Technologies Japan, Ltd.
  • Page 3: Safety Summary

    WARNINGS In addition it violates safety standards of design, manufacture, and intended use of the instrument. The Agilent Technologies assumes no liability for the customer's failure to comply with these requirements. DO NOT Operate In An Explosive Atmosphere Do not operate the instrument in the presence of ammable gasses or fumes. Operation of any electrical instrument in such an environment constitutes a de nite safety hazard.
  • Page 4: Certi Cation

    Agilent Technologies. Buyer shall prepay shipping charges to Agilent Technologies and Agilent Technologies shall pay shipping charges to return the product to Buyer. However, Buyer shall pay all shipping charges, duties, and taxes for products returned to Agilent Technologies from another country.
  • Page 5: General Information

    General Information Introduction The purpose of this manual is to enable you to use your 16089E Kelvin Clip Leads eciently and con dently. This manual contains both general and speci c information. Product Description The 16089E has been designed to operate speci cally with the following four-terminal-pair type...
  • Page 6 Operating and Safety Precautions Operating You need observe only normal precautions in handling and operating the 16089E. Do not exceed the operating input power, voltage, and current level and signal type appropriate for the instrument being used, refer to your instrument's operation manual.
  • Page 7: Speci Cations

    Speci cations These speci cations are the performance standards and limits against which the 16089E is tested. When shipped from the factory, the 16089E meets the following speci cations: Applicable Instrument 4263B, 4278A , 4284A , 4285A : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : :...
  • Page 9: Initial Inspection

    This chapter explains how to use the 16089E Kelvin Clip Leads. Initial Inspection The 16089E has been carefully inspected electrically and mechanically before being shipped from the factory. It should be in perfect physical condition, no scratches, dents or the like, and they should be in perfect electrical condition.
  • Page 10 Alteratively, comparable packaging materials may be used. Wrap the test leads in heavy paper and pack in anti-static plastic packing material. Use sucient shock absorbing material on all sides of the 16089E to provide a thick, rm cushion and to prevent movement. Seal the shipping container securely and mark it...
  • Page 11: Operation

    Operation Step-by-step instructions on how to make a measurement with the 16089E are as follows: 1. Set the instrument's Cable Length setting to 1 m. 2. Connect the 16089E to the instrument's UNKNOWN terminals. Figure 2-2. Connecting the Test Leads 3.
  • Page 12 OPEN and SHORT Compensation The 16089E has inherent stray capacitance, residual inductance, and residual resistance that a ect the measurement. To cancel the e ects caused by these residuals and thus minimize their e ect on measurement accuracy, the instrument's OPEN and SHORT compensation capabilities must be used.
  • Page 13 REGIONAL SALES AND SUPPORT OFFICES For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir. You can also contact one of the following centers and ask for a test and measurement sales representative.