Power Supply - Planar Dome E2 User Manual

Display; display controller
Hide thumbs Also See for Dome E2:
Table of Contents

Advertisement

Power Supply

CAUTION: Use only the power adapter supplied with the Dome E2 display unit;
Ault MW116KA1249F53.
Category
Power input
requirements
Power output
requirements
Physical
Reliability
Characteristic item
Display
Backlight
Environment
Characteristic item
EMI shielding
Temperature
Humidity
Characteristic Item
Voltage selection
Voltage
Current
Frequency
Voltage
Current
Size
Weight
Specification
MTBF >50,000 hours
MTBF 50,000 hours to 50% brightness with backlight on continuously
operating
storage
operating
storage
Specification
Auto-ranging
100 – 240V AC
1.0 A
50 to 60 Hz
±
12 V DC
5%
6.67 A (80 W)
127.0 mm x 76.2 mm x 44.5 mm
(5 in x 3 in x 1.75 in)
0.7 kg (1.5 lb)
Specification
No emission of low-level radiation
0° C to 40° C
-10° to 60° C
10% to 80% Relative Humidity
(non-condensing)
5% to 90% Relative Humidity
(non-condensing)
Dome E2 Specification | 15