5 Troubleshooting
Log of Past Errors
Open the Sysmac Studio's Controller Event Log Tab Page to check the times, levels, sources, source
details, event names, event codes, details, attached information 1 to 4, and corrections for previous
errors.
Additional Information
Number of Logs of Past Errors
Event logs in the System Units are stored in the CPU Unit, Communications Coupler Unit, or
Communication Control Unit to which they are connected.
Refer to the software user's manual for the connected CPU Unit, or the user's manual for the
Communications Coupler Unit or Communication Control Unit for details on the amount of event
logs that are stored in the Unit.
Refer to the troubleshooting manual for the connected CPU Unit or Industrial PC and the Sysmac
Studio Version 1 Operation Manual (Cat. No. W504) for information on the items you can check and
for how to check for errors.
Refer to 5-3-3 Event Codes and Corrections for Errors on page 5-6 for details on event codes.
5-3-2
Checking for Errors from Support Software Other Than the Sys-
mac Studio
You can check the error descriptions and logs with Support Software other than the Sysmac Studio.
For the error checking methods, refer to the user's manual for the connected Communications Coupler
Unit and the operation manual for the Support Software.
Refer to 5-3-3 Event Codes and Corrections for Errors on page 5-6 for details on event codes.
The number of current errors and the number of error log errors that occurred in the past in the Sys-
tem Units are the same as for the Sysmac Studio.
5-3-3

Event Codes and Corrections for Errors

The errors (i.e.,events) that can occur in the System Units are given below.
If your NX Unit is connected to a Communication Control Unit, replace CPU Unit with Communication
Control Unit in the descriptions provided for "For the NX bus of CPU Units" in the table below.
The following abbreviations are used in the event level column.
Abbrevi-
ation
Maj
Major fault level
Prt
Partial fault level
Min
Minor fault level
Obs
Observation
Info
Information
Refer to the troubleshooting manual for the connected CPU Unit or Industrial PC for all NJ/NX/NY-ser-
ies event codes.