When you use any ferrules other than those in the above table, crimp them to the twisted wires so
that the following processed dimensions are achieved.
1.6 mm max. (except ground terminals)
2.0 mm max. (ground terminals)
 Using Twisted Wires/Solid Wires
If you use twisted wires or solid wires, use the following table to determine the correct wire specifi-
cations.
Terminals
Classifica-
tion
All termi-
nals except
ground ter-
minals
Ground
terminals
*1. Secure wires to the screwless clamping terminal block. Refer to Securing Wires on page 4-51 for how to
secure wires.
*2. With the NX-TB£££1 Terminal Block, use twisted wires to connect the ground terminal. Do not use a
solid wire.
Conductor length (stripping length)
NX-series System Units User's Manual (W523)
Twisted wires
Current
Unplat-
Plated
capacity
2 A max.
Possible
Possible
Greater
Not pos-
than 2 A
sible
and 4 A or
less
Greater
Possi-
than 4 A
*1
ble
---
Possible
Possible
8 to 10 mm
2.4 mm max. (except ground terminals)
2.7 mm max. (ground terminals)
Wire type
Solid wires
Unplat-
Plated
ed
ed
Possible
Possible
Possi-
Not pos-
sible
*1
ble
Not pos-
sible
Possi-
Possi-
*2
*2
ble
ble
4 Installation and Wiring
Conductor
Wire size
length (strip-
ping length)
8 to 10 mm
2
0.08 to 1.5 mm
(AWG28 to 16)
9 to 10 mm
2
2.0 mm
4
4-47