Switches And Sensors - Olivetti DP-700 Service Manual

Table of Contents

Advertisement

3JX

(2) Switches and sensors

5
6
1.
DP safety switch 1 (DPSSW1)..................... Breaks the safety circuit when the document processor is opened; resets
2.
DP safety switch 2 (DPSSW2)..................... Breaks the safety circuit when the top cover is opened; resets original
3.
Original set switch (OSSW) ......................... Detects the presence of an original.
4.
Original feed switch (OFSW) ....................... Detects primary original feed end timing.
5.
Original registration switch (ORSW) ............ Detects the original conveying timing.
6.
DP timing switch 1 (DPTSW1) ..................... Detects the original scanning timing.
7.
DP timing switch 2 (DPTSW2) ..................... Detects the original scanning timing.
8.
Original length size switch (OLSW) ............. Detects the length of the original.
9.
Original width size switch (OWSW) ............. Detects the width of the original.
10. DP lift upper limit switch (DPLULSW) .......... Detects the original tray reaching the upper limit.
11. DP lift lower limit switch (DPLLLSW) ........... Detects the original tray reaching the lower limit.
12. CIS open/close switch (CISOCSW) ............. Detects the opening/closing of the top cover.
2-2-2
10
12
4
3
11
7
Machine front
Figure 2-2-2 Switches and sensors
original misfeed detection.
misfeed detection.
9
Machine inside
Service Manual
8
2
Machine rear
1
Y106871-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Y106871-5

Table of Contents