LD 73 — Define TOLT and TOLL pad levels prompts and responses (Part 2 of 2)
Prompt
Response
...
...
TOLT
Rx Tx
(0)(0)
TOLL
Rx Tx
(16)(30)
Hardware requirements
Description
...
Toll Call Pad data on DTI2 card.
Default values 0 dB Receive, 0 dB Transmit
(Valid range 0 – 26, see Table 24)
Toll Call Pad data on DTI2 card.
Default values 0 dB Receive, 7 dB Transmit
(Valid range Rx: 0 – 31, Tx: 8 – 39, see Table 16 or
Table 22)
Dynamic Loss Switching requires the following cards:
•
NT5K02XFALC with Message Waiting
•
NT5K17XDDI
•
NT5K18XCOT
•
NT5K19XFEM
•
NT5K82XCOT
•
NT5K83XFEM
•
NT5K84XDDI
•
NTRA02XUTC
•
NTRA03XEMC
•
NTRA04XFALCC with Message Waiting
•
NTRA05XALCC without Message Waiting
•
NTRA06XOPSC Off-premises Station
Dynamic Loss Switching
Transmission Parameters
Page 105 of 236
Australia
New Zealand
New Zealand
New Zealand
New Zealand
Australia
Australia
Australia
China
China
China
China
China