Spurious out-of-band
Discrimination against out-of-band signals
Transmission characteristics for PE
Transmission characteristics—A-Law
Table 53 specifies the image signal level required for out-of-band frequencies
as measured selectively at the output port.
Table 53
Spurious out-of-band image signals—A-Law
Input signal
0 dBm0 (300 Hz–3.4 kHz)
Table 54 specifies the image signal level required for the designated input
signals as measured at the output port.
Table 54
Discrimination against out-of-band signals—A-Law
Input signal
–25 dBm0 (above 4.6 kHz)
The transmission characteristics for PE are the same as for A-law IPE (see
Tables 41 through 54). The PE overload levels are the same as for the µ-Law
overload levels in Table 56.
Image signal level
(above 3–4 kHz)
< –25 dBm0
Image signal level
(at any frequency)
25 dB below level of test signal
Transmission Parameters