JUKI DDL-900B Instruction Manual page 36

Table of Contents

Advertisement

No.
Item
*
177 Thread clamp AK oper-
ating time
181 Setting of a target value
for the production sup-
port function
182 Operation to be con-
ducted when the target
value is achieved
183 Setting of the number of
times of thread trimming
for the production sup-
port function
*
186 Soft start resetting angle An angle at which the start is reset is set.
187 Thread clamp sewing
speed resetting angle
* Do not change the set values with asterisk (*) mark as they are functions for maintenance. If the standard set value set at the time of
delivery is changed, it is in danger of causing the machine to be broken or the performance to be deteriorated. If it is necessary to
change the set value, please purchase the Engineer's Manual and follow the instructions.
[Function setting of thread clamp device]
No.
Item
15 Thread clamp function at
the start of sewing
20 Changeover of thread
clamp/wiper
27 Thread clamp sewing
speed
37 Sewing speed of soft-start Sewing speed at the start of sewing (soft-start) (The MAX value differs by
151 Thread clamp ON angle
152 Thread clamp OFF angle The angle at which the thread clamp is turned OFF at the start of sewing is
177 Thread clamp AK operat-
ing time
186 Soft start resetting angle
187 Thread clamp sewing
speed resetting angle
Description
Function for setting the time for turning ON the AK which operates when
the thread clamp is used.
A target value for the sewing counter of the production support function
is set.
Operation to be carried out when the sewing counter of the production
support function reaches the target value is set.
0 : No operation
1 : The sewing machine does not operate even if the pedal is de-
pressed.
* In the case the function No. 13 is used, the setting of the function No.
182 is disabled.
The number of times of thread trimming at which the sewing counter of
the production support function stops counting is set.
0 : The sewing counter stops counting when a value is entered to the
sewing counter using the optional input/output function.
1 to 20 : The sewing counter stops counting according to the preset
number of times of thread trimming
* This setting is enabled when the thread clamp operates.
This function item is used for setting the angle at which the sewing speed
employed while the thread clamp is operating is reset.
* This setting is enabled when the thread clamp operates.
Operation of the thread clamp at the start of sewing is set.
0 : Thread clamp does not operate
1 : Thread clamp operates
Function of thread clamp/wiper operation is changed over.
0 : Thread clamp operation
1 : Wiper operation
The sewing speed when the thread clamp operates is set.
machine head.)
The angle at which the thread clamp is turned ON at the start of sewing is
set.
set.
Function for setting the time for turning ON the AK which operates when the
thread clamp is used.
When the setting is "0", AK does not operate.
An angle at which the soft-start (No.37) is reset is set.
* This setting is enabled when the thread clamp operates.
An angle at which the thread clamp sewing speed (No.27) is reset is set.
* This setting is enabled when the thread clamp operates.
Description
– 34 –
Setting range
Default
page
0 to 1000
4 2
(ms)
0 to 9999
0
0/1
0
0 to 20
1
180 to 900
7 8 0
(°)
0 to 720 (°)
1 3 0
Setting range
Default
0/1
0/1
100 to MAX
3 0 0
(sti/min)
100 to MAX (sti/
8 0 0
min)
180 to 290 (°)
2 1 0
210 to 359 (°)
2 9 0
0 to 100 (ms)
4 2
180 to 900 (°)
7 8 0
0 to 720 (°)
1 3 0
Ref.
1
1

Advertisement

Table of Contents
loading

Table of Contents