Main Barrier - Electrolux W585S Service Manual

Hide thumbs Also See for W585S:
Table of Contents

Advertisement

80
12:253 JUMPER 1
The error code is shown if input JUMPER 1 is not activated.
Jumpers are a by-pass of inputs not used in the machine. How many jumpers used is depending on configuration.
When the jumper is restored the error code is automatically reset and the ongoing program will continue. A long
press on the control knob/start button will make the control system reset and ongoing program will be ended.
Recommended actions:
Check the harness, connectors and functions by reading the electrical schematic and by using the SHOW INPUTS
menu when the machine is in service mode.
12:254 JUMPER 2
The error code is shown if input JUMPER 2 is not activated.
Jumpers are a by-pass of input not used in the machine. How many jumpers used is depending on configuration.
When the jumper is restored the error code is automatically reset and the ongoing program will continue. A long
press on the control knob/start button will make the control system reset and ongoing program will be ended.
Recommended actions:
1. Check the harness, connectors and functions by reading the electrical schematic and by using the SHOW INPUTS
menu when the machine is in service mode.
12:255 JUMPER 3
The error code is shown if input JUMPER 3 is not activated.
Jumpers are a by-pass of input not used in the machine. How many jumpers used is depending on configuration.
When the jumper is restored the error code is automatically reset and the ongoing program will continue. A long
press on the control knob/start button will make the control system reset and ongoing program will be ended.
Recommended actions:
1. Check the harness, connectors and functions by reading the electrical schematic and by using the SHOW INPUTS
menu when the machine is in service mode.

MAIN BARRIER

13:1 DRUM POSITIONING TIMED OUT
The error code is shown if input POSITION DRUM 1 and POSITION DRUM 2 is not activated within set time in Con-
fig parameter DRUM POS TIMEOUT.
Recommended actions:
1. Check inputs from positioning sensors DP1 and DP2.
13:2 DRUM LOCKING / UNLOCKING
The error code is shown if drum is not able to unlock/lock when expected.
This is detected by the input sensors DRUM UNLOCKED (FC1) and DRUM LOCKED (FC2).
Recommended actions:
1. Check functionality of drum lock position sensors FC1 and FC2.
2. Check functionality of drum locking piston, i.e that it operates normall and could activate/inactivate. This could be
done by running a positioning sequence in service program or by running a program.
13:3 INNER DOOR OPENING
Machine indicates that the automatic inner door JACK (Piston) has not left the home position within a reasonable
time.
The error code is shown if the sensor for JACK AT HOME (backwards position) is still active when JACK is expected
to be in forward position.
Recommended actions:
1. Check functionality JACK_AT_HOME sensor DP6, i.e active when jack is in backward position, inactive when
JACK is in forward position.
2. Check functionality for JACK, I.e that it could move forward when expected.