10 Barrier partition

Leave at least 1 m (40") (according to the recommendation in standard EN 60204) between the machine, a wall or
any other machine at the sides.
mm/in
A
WPB4 700H
1570
WPB4 900H
1800
WPB4 1100H
2030
* Minimum 70 mm (2.76"),, maximum 100 mm (4"),.
• The barrier partition (O) shall be built before the installation of the machine.
• Centre and align the washer-extractor with the frame (P) 60x100mm (2x4") maximum (provided by customer)..
• Place the rubber seal (R) inside the aluminium extruded section (S).
• Screw the aluminium extruded section (S) on the frame or on the optional plates (P).
If machines are to be installed in an existing wall thicker than 100 mm (4"), we recommend you order our special
aseptic frame kit.
Installation manual
B
C
2080
2040
2080
2040
2080
2040
D
1490
1720
1950
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wp4 900hWp4 1100hWpb4 700hWpb4 900hWpb4 1100h

Table of Contents