52:2 DMIS COMMUNICATION ERROR
This is a warning message that will be shown for 5 seconds if there is a problem in DMIS communication, i.e. the
communication between the machine and a external detergent dosing system.
Warning is shown if system has been up running once and then is interrupted or working intermittent.
The warning will be shown at program start for 5 seconds, the next 5 programs. It is then removed automatically.
After the warning message has dissapeared the machine will start, but there is a risk the wash will run without any ex-
ternal detergent dosing.
Possible causes:
• The external dosing system has been disconnected, switched off or broken.
• Machine adress in machine has been changed and this is also used by external dosing system.
Recommended actions:
1. Check connections, cables or network between machine and detergent dosing system.
2. Consult the supplier for external dosing system.

INTERNAL

60:5 FATAL ERROR INVALID RUNNING MODE
The control system has an internal error during memory read.
Recommended actions:
1. Press the control knob/start button to retry.
2. If problem persists, upload new software.
60:11 FATAL ERROR EXTERNAL FLASH WRITE
The control system has an internal error during memory read.
Recommended actions:
1. Press the control knob/start button to retry.
2. If problem persists, upload new software.
60:17 FATAL ERROR INVALID OPTION
The control system has an internal error during memory read.
Recommended actions:
1. Press the control knob/start button to retry.
2. If problem persists, upload new software.
60:18 FATAL ERROR INVALID MODULE
The control system has an internal error during memory read.
Recommended actions:
1. Press the control knob/start button to retry.
2. If problem persists, upload new software.
60:28 FATAL ERROR INVALID COIN INPUT
The control system has an internal error during memory read.
Recommended actions:
1. Press the control knob/start button to retry.
2. If problem persists, upload new software.
60:29 FATAL ERROR INVALID FONT
The control system has an internal error during memory read.
Recommended actions:
1. Press the control knob/start button to retry.
2. If problem persists, upload new software.