11:28 WATER LEVEL HIGH DLCU LEVEL LOW
The DLCU on I/O type 10 contains a mechanical DLCU level switch which ensures that there is no water in the ma-
chine when the door unlocks. To ensure that the DLCU level switch functions correctly, the DLCU level switch status
is compared with a predefined value from the electronic level sensor. During first fill, this check is made to ensure that
the mechanical level switch is activated when the water level exceeds the predefined value. If not, this error code is
shown.
Predefined level value is defined in Config. 2 parameter LEVEL DLCU.
Possible causes:
• The mechanical level control can be damaged.
• Leakage or clogged level controls air hoses.
Recommended actions:
1. Check function of mechanical level switch by reading DLCU status in service mode.
2. Check the analog level control function by checking value in inputs.
3. Blow through the level hoses and check that they are not blocked and does not contain any water.
4. Check the cables and their connections.
11:29 WATER LEVEL LOW DLCU LEVEL HIGH
The DLCU on I/O type 10 contains a mechanical DLCU level switch which ensures that there is no water in the ma-
chine when the door unlocks opens. To ensure that the DLCU level switch functions correctly, the DLCU level switch
status is compared with the value from the electronic level sensor. At program start and program end, when the water
level is below LEVEL EMPTY value, a check is made to ensure that the mechanical level switch is not activated If it is
activated, this error code is shown.
The level empty value is defined in Config. 2 parameter LEVEL EMPTY.
Possible causes:
• The mechanical level control can be damaged.
• Mechanical level control is not connected or bad there is bad contact in the connector.
• Leakage or clogged level controls air hoses.
• Incorrect nominal value, possibly caused by a error in the electronic level control.
Recommended actions:
1. Check function of mechanical level switch by reading DLCU status in service mode.
2. Check the analog level control function by checking value in inputs.
3. Blow through the level hoses and check that they are not blocked and does not contain any water.
4. Check the cables and their connections.
11:126 CO2 BOTTLE EMPTY
This is only a warning message.
Shown when CO2 bottle is about to be empty and input CO2 BOTTLE EMPTY is actvated.
Program will continue when message has dissappeared.
11:127 DRAWER OUT CLOSE TO START
This is only a warning message.
Shown if input DETERGENT BOX SENSOR is active at program start or during program run if water is supposed to flush
in detergent compartment.
The program will pause until input DETERGENT BOX SENSOR is deactivated.
The function to check for open detergent box can be turned off in Config 1 DETERGENT BOX SENSOR.