INTERNAL COM. I/O TYPE 6

42:1 I/O TYPE 6 INTERNAL ERROR
I/O unit type 6, reading of internal analog values out of range.
Possible causes:
• Intermittent error in wiring to I/O type 6 unit.
• Internal error in I/O type 6.
Recommended actions:
1. Switch power off for 1 minute and try again.
2. If problem remains, replace defective part.
42:2 I/O TYPE 6 POSITION TEST
Position test is used to verify that I/O type 6 unit is correctly assembled and fixed in the expected position.
Recommended actions:
1. Check that I/O type 6 unit is assembled and fixed in correct position.
42:3 I/O TYPE 6 EXTRACT TEST
I/O unit type 6 is not able to read any or too low values during extraction.
Recommended actions:
1. Check that I/O unit type 6 unit is assembled and fixed in correct position.
2. Put some unbalance in drum and run motor to extraction speed in service program.
Check analog input readings for I/O 6.

EXTERNAL COM. PAYMENT

51:22 NO CBT COMMUNICATION PRESS TO RETRY
Machine connected to payment system using serial communication to machine.
Cause:
• Communication has been established once and then interupted.
Recommended actions:
1. Check electrical connections between CPU and payment system.
2. If running in a network, check network cables between machine and payment system.
3. Check that payment system is operational.
4. Check that payment system and machine is configured to the same Machine adress (Config 1).
5. To reset machine to working state without repairing payment system, use Reset CBT communication in service
mode. (Requires password).

EXTERNAL COM. CMIS

52:1 CMIS COMMUNICATION ERROR
Communication between machine and CMIS computer has been interrupted.
The warning will be shown at program start for 5 seconds, the next 5 programs. It is then removed automatically.
After the warning message has disapeared the machine will start, but no CMIS data statistics/data will be logged.
Possible causes:
• If using ELS Common Service Tool process viewer and cable has been unplugged before process viewer has
been stopped, this warning will occur.
• If running with ELS CMIS and communication is interrupted to PC, warning will occur.
Recommended actions:
1. If using ELS CST, reconnect, enter Process viewer and select function "Reset MIS communication".
2. If using ELS Network and CMIS:
Check ELS network cable between machine and PC.
Check that CMIS application is active and running normally.
For CMIS:The machine can operate but statistics will be affected and data will be lost.