Download Print this page

KTM 350 EXC-F 2022 Setup Instructions page 30

Hide thumbs Also See for 350 EXC-F 2022:

Advertisement

3 WORK
28
Pull back positive terminal cover
positive cable from the 12-V battery.
(EXC‑F AR/BR, EXC-F SIX DAYS BR)
Warning
Risk of injury Battery acid and battery gases cause
serious chemical burns.
Disconnect negative cable
Pull back positive terminal cover
positive cable from the 12-V battery.
Pull off starter relay
compartment and hang to the side.
V01777-10
Detach wiring harness
them to the side.
V01778-10
2
and disconnect the
Keep 12 V batteries out of the reach of chil-
dren.
Wear suitable protective clothing and safety
glasses.
Avoid contact with battery acid and battery
gases.
Keep sparks or open flames away from the
12 V battery.
Only charge 12 V batteries in well-ventilated
rooms.
Rinse the affected area immediately with
plenty of water in the event of contact with the
skin.
Rinse eyes with water for at least 15 minutes
and consult a doctor immediately if battery
acid and battery gases get into the eyes.
1
from the 12-V battery.
2
and disconnect the
3
4
and fuse box
from the battery
5
, disconnect relays
6
and hang

Advertisement