Advertisement

Horizontal flue with 2 x 90° bends
Table 13
High level horizontal flue
High level horizontal flue
Table 14
High level horizontal flue with additional elbows
High level horizontal flue with 2 x 90° bends
Table 15
High level horizontal flue with additional elbows
High level horizontal flue with 3 x 90° bends
Table 16
Greenstar Ri Compact
ErP
6720813282 (2015/07)
Vertical balanced flue assembly
Maximum flue length
(mm)
60/100
80/125
2,000
11,000
Vertical balanced flue assembly
Table 17
Vertical balanced flue with elbow offset (2 x 90 ° bends)
Maximum flue length
(mm)
60/100
80/125
6,000
15,000
Vertical balanced flue with 2 x 90° bends
Table 18
Maximum flue length
Vertical balanced flue with elbow offset (2 x 45 ° bends)
(mm)
60/100
80/125
4,000
13,000
Vertical balanced flue with 2 x 45° bends
Table 19
Maximum flue length
(mm)
60/100
80/125
2,000
11,000
A = 300 mm
B = 500 mm
Maximum flue length
60/100
6,000
Maximum flue length
60/100
2,000
Maximum flue length
60/100
4,000
Pre-installation
(mm)
80/125
15,000
(mm)
80/125
11,000
(mm)
80/125
13,000