Greenstar cdi classic regular wall hung rsf gas fired condensing regular boiler, for open vented and sealed central heating systems and indirect domestic hot water (48 pages)
USER INSTRUCTIONS WALL HUNG RSF GAS FIRED CONDENSING SYSTEM BOILER GREENSTAR CDi CLASSIC SYSTEM FOR CENTRAL HEATING SYSTEMS AND INDIRECT FED DOMESTIC HOT WATER The appliance is for use with: Natural Gas or L.P.G. (CAT II 2H3P type C13 & C33)
3.9 Fault condition ......12 and labour guarantee - backed up by Worcester Total Cover, an optional complete maintenance scheme to keep your boiler operating at peak condition and efficiency.
▶ Before starting electrical work: – Isolate the mains electrical supply and secure against unintentional reconnection. – Check for zero potential. ▶ Also observe connection diagrams of other system components. GREENSTAR CDi CLASSIC SYSTEM – 6 720 812 178 (2014/07)
Raise standards among professional installers • Build and maintain high safety standards in the industry • Improve customer satisfaction levels • Make a contribution to the nation's commitment to climate change GREENSTAR CDi CLASSIC SYSTEM – 6 720 812 178 (2014/07)
(only in conjunction with optional diverter valve) [9] ON/OFF and fault indicator (Blue) [10] Central heating temperature control [11] Central heating boost button [12] Service button [13] Burner indicator (Green) GREENSTAR CDi CLASSIC SYSTEM – 6 720 812 178 (2014/07)
This occurs every time the mains supply has been interrupted. Switching off ▶ Switch off the boiler by pressing the ON/OFF button. The ON/OFF indicator light [1] goes out. GREENSTAR CDi CLASSIC SYSTEM – 6 720 812 178 (2014/07)
▶ For further information on how to control your central heating system please refer to the individual user guides for the programmer or timer installed in your home. GREENSTAR CDi CLASSIC SYSTEM – 6 720 812 178 (2014/07)
▶ Turn the domestic hot water temperature control [1] to the desired level, between approximately 40°C and 60°C. Position Hot water temperature approx. 40 °C approx. 50 °C approx. 60 °C Table 3 Settings for the domestic hot water temperature GREENSTAR CDi CLASSIC SYSTEM – 6 720 812 178 (2014/07)
▶ Ensure the installer has fitted a frost thermostat in the area to protect the pipework from freezing. ▶ Ensure the installer has added a suitable anti-freeze fluid to the water in the central heating system. GREENSTAR CDi CLASSIC SYSTEM – 6 720 812 178 (2014/07)
To re-activate eco mode: ▶ Press the eco button until it lights up. When the eco button is illuminated the appliance switches between central heating mode and cylinder charging mode. GREENSTAR CDi CLASSIC SYSTEM – 6 720 812 178 (2014/07)
Frost protection remains active. To deactivate holiday mode: ▶ Press the holiday button until it goes off. When the holiday button is not illuminated, the appliance runs in normal mode. GREENSTAR CDi CLASSIC SYSTEM – 6 720 812 178 (2014/07)
13 of these user instructions. ▶ Call Worcester, Bosch Group, giving a description of the fault and, if possible, the fault code from the display. Alternatively contact other Gas Safe registered personnel for assistance. GREENSTAR CDi CLASSIC SYSTEM – 6 720 812 178 (2014/07)
MAINTENANCE Your new Greenstar CDi Classic System gasfired appliance If you would like to know more about a Worcester Bosch service represents a long term investment in a reliable, high quality contract, please tick the appropriate box on your warranty product.
Maintenance ERROR CODES When calling Worcester, Bosch Group, you may be asked for the error code. This Table is for you to help identify the possible cause of the fault. ▶ Do not try to rectify any of the faults listed below by yourself.
600 mm service clearance required to a fixed surface 0330 123 9559. 20 mm from removable door or panel ▶ Contact your installer in order to find a permanent solution to the problem. GREENSTAR CDi CLASSIC SYSTEM – 6 720 812 178 (2014/07)
▶ Do not restrict this space with the addition of cupboards, FAULT OR BREAKDOWN shelves etc. around or next to the boiler. This boiler is supported in the UK and Eire by Worcester, Bosch VENTILATION Group. This is a room sealed boiler and does not require any air for Specialist Service Engineers are available to attend a combustion from inside the property.
PVCu or wooden framed double glazing units. CURTAINS Lined curtains, or heavier full length curtains can provide excellent insulation. However, always ensure that the curtains do not drape over radiators. GREENSTAR CDi CLASSIC SYSTEM – 6 720 812 178 (2014/07)
Name of Installer Telephone number of Installer Table 6 1) See boiler identification label on boiler fascia or Benchmark Checklist in the back of the Installation, Commissioning & Servicing Instructions. GREENSTAR CDi CLASSIC SYSTEM – 6 720 812 178 (2014/07)
It is recommended that this type of valve is fitted to all but one of the radiators. The remaining radiator, where the room thermostat is located, must be uncontrolled and left open. GREENSTAR CDi CLASSIC SYSTEM – 6 720 812 178 (2014/07)
Page 20
0330 123 9119 TRAINING: 0330 123 0166 SALES: 0330 123 9669 Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW. Tel. 0330 123 9559 Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. worcester-bosch.co.uk 6 720 812 178...