IKONIC Tankless Water Heater Service Manual
HOW TO REMOVE COMPONENTS

IGNITER COIL

1. Remove the hook film part of the Over Heat Limiter
(OHL).
2. Remove Igniter rod cover.
3. Remove igniter coil wire from igniter rod (left side).
Flame Rod
Igniter Rod
4. Remove white Molex connector from igniter coil.
74
5. Remove the screw (pictured below) from the igniter
bracket.
White Molex Connector
Screw