9.1.3 Damper Test Mode

Damper Test Mode gives the user the ability to open
specific dampers to verify the dampers are performing
properly. Each damper can be driven independently or in
any combination. The blower will operate during an active
damper test. The blower speed is determined by the sum
of the Zone Size's of each damper selected to be tested.
Damper Test Mode will automatically timeout after 30
minutes or immediately if "Stop" is pressed.
Upon entering Damper Test Mode, all system operation
will stop and each damper will be driven full open. Once a
damper(s) is selected for test, the non-selected dampers
will be driven fully closed.
9.2

Save Logs

The 1050 Control has the ability to log data on USB Flash
Drive. Attach a USB Flash Drive to the included USB
connector, plug it into the 1050 Control and select Save
Logs from the Service Menu.
Access Save Logs by navigating to Service Menu>Save Logs.
9.3

Diagnostics

9.3.1 Alerts

Within the Diagnostic screen are two items related to alerts:
Current Alerts – Alerts which are currently active
Alert History – Cleared Alerts (last 30 days)
NOTE: Each alert will have a date/timestamp of when the
alert was negated. The Date/Time stamp for Current Alerts
is when the alert was asserted. For Alert History the date/
timestamp is when the alert was negated.
From both screens the user can select an alert code and
get additional information on the alert as well as a list of
possible causes, similar to the Interactive Troubleshooting
Guide located on ComfortSite/ASDealernet
All alerts are categorized by severity:
CRITICAL
— Loss of heating/cooling operation
— Service call is required
— Alert messages are displayed on the home screen
MAJOR
— Reduced functionality - minimum operation is possible
— Service call is not immediately required
— Alert messages are not displayed on the home screen
NORMAL
— Functionality may be lost but should recover or the
information is for diagnostic purposes / performance
monitoring
— Service call is not required
— Normal alerts are only displayed in the Diagnostic
screen
Diagnostics
can
be
Service Menu>Diagnostics.
18-HD80D1-3-EN
accessed
by
navigating

9.3.2 Summary Table

The 1050 Control has a Summary Table which lists all
the communicating devices that have been discovered.
In addition to viewing the status of each communicating
device, the Summary Table can be used to remove "offline"
devices. The screen is made up of three fields:
Device Information: Lists the device name and model/
serial number
Enabled: Identifies whether the device has been
enabled
Status: Identifies whether the device is currently
reporting on the bus (Only "Offline" devices can be
removed)
The Enabled and Status field can be used to troubleshooting/
informational purposes:
Enabled + Online: Device has been enabled and is
currently reporting on bus
Enable + Offline: Device has been enabled but is not
reporting (Err.126.00 will typically be triggered during
this condition).
Disabled + Online: Device has not been enabled but
is reporting (verify device has been configured in the
installer settings).
Disabled + Offline: Device has not been enabled and
is currently not reporting.
9.4

History

History is accessed by navigating to Service Menu>History
The History screen allows the technician to view cycle
count and a sum of the run time in minutes for each mode
and stage of operation. This data provides a snap-shot into
system operations.
SYSTEM HISTORY TABLE
TODAY
Y1 Cooling
56
Y2 Cooling
Y1 Heating
Y2 Heating
W1
W2
W3
Defrost Cycles
ZONE HISTORY TABLE
Relief Cycles
2
Cooling over-
shoot > 2.5°
Heating Over-
shoot > 2.5°
Indicates cycle count
1
to
2
Indicates cycle time in minutes
LAST 7
CURRENT
DAYS
MONTH
/784
206
/2412
1188
/10692
1
2
1
2
1
/26
5
/48
14
/112
1
2
1
2
1
1/--
4/--
8/--
0/--
1/--
3/--
XL 1050
LAST
MONTH
2046
/16368
2
1
2
19
/137
2
1
2
4/--
6/--
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comfortlink ii xl1050

Table of Contents