6.7

System Mode

The 1050 Control has (5) System Modes which can be
selected...Heating, Cooling, Off, Emergency Heat and
Auto.
Heating – System will only operate in heating mode
Cooling – System will only operate in the cooling
mode
Off – System will not operate in heating or cooling
mode
Emergency Heating – System will operate the indoor
heat source only (this is only available when the
outdoor unit type is a heat pump)
Auto - The 1050 Control will determine which mode of
operation based on the following rules:
• Heating - Indoor temperature is equal or less than
heating setpoint
• Cooling – Indoor temperature is equal to or greater
than cooling setpoint or within 1°F of cooling setpoint
There is minimum deadband between heating and cooling
setpoints of 3°F (4°F when zoning is applied).
6.8

Quiet Mode (VSPD Systems Only)

Quiet Mode limits compressor operation (heating and
cooling mode) to minimum speed from 10 p.m. to 9 a.m.
This is to support local noise ordinances in the upper
northwest and other regions.
Charcteristics of Quiet Mode
During heating mode, indoor heat is allowed if the
system cannot maintain space conditions while Quiet
Mode is active
Quiet Mode is disabled by default. To enable press
"System Mode" on the home screen, then select
"System Options" and "Enable"
When active, Quiet will be displayed below the indoor
temperature on the 1050 Control's home screen
6.9

Fan Mode

The 1050 Control has three Fan Modes:
Auto – Fan only runs with a call for heating or cooling
On – Fan runs continuous
Circ – Fan runs a user selected minimum amount of
time each hour
18-HD80D1-3-EN

6.10 Air Cleaner Mode

The 1050 Control has three Air Cleaner modes:
Auto – Air cleaner operates only with a call for fan
operation
Quick – Air cleaner will operate for 3-hours with
blower at 100%
Allergy – Air cleaner will operate for 24-hours with
blower at 100%
Note: If a communicating Air Cleaner is installed, the power
level will be set to High during Quick and Allergy Clean
Modes.