Sign In
Upload
Manuals
Brands
Trane Manuals
Control Unit
VAV-UCM 4.2
Trane VAV-UCM 4.2 Manuals
Manuals and User Guides for Trane VAV-UCM 4.2. We have
1
Trane VAV-UCM 4.2 manual available for free PDF download: Installation & Maintenance Manual
Trane VAV-UCM 4.2 Installation & Maintenance Manual (88 pages)
Unit Control Module
Brand:
Trane
| Category:
Control Unit
| Size: 6.71 MB
Table of Contents
Table of Contents
3
General Information
6
Chapter Overview
6
Unit Control Module 4.2 (UCM 4.2)
6
Specifications
6
UCM 4.2 Enhancements
7
UCM 4.2 Features
7
Shipping
8
Storage
9
VAV Start Up/Check out Procedure
10
Chapter Overview
10
UCM 4.2 Pre-Power Check-Out
10
Light Emitting Diode (LED) Operations
10
Zone Sensor Check-Out
11
UCM 4.2 Installation and Wiring
12
Chapter Overview
12
UCM 4.2 Power Wiring
12
Power Requirements
12
Zone Sensor Wiring
13
Location and Mounting
13
Wiring
13
Multiple Ucm's Per Zone Sensor
14
Multiple Ucm's Per Auxiliary Duct Temperature Sensor
14
Zone Sensor Hardwired Option
14
Zone Sensor Wireless Option
14
Communication Wiring
15
Communication Link Wiring
15
DIP Switch Settings
16
Wireless Zone Sensor
21
Overview
21
Dimensional Diagrams
21
Setting the Address, Mounting, Wiring, and Associating the Receiver and Sensor
22
Choosing a Location for Mounting the Sensor
23
Setting the Rotary Address Switches on the Receiver and the Sensor
23
Factory Wiring of the Receiver to the VAV UCM
25
Replacing and Securing the Receiver Cover
26
Applying Power to the Receiver
27
Powering the Sensor and Associating the Sensor to the Receiver
28
Testing Signal and Battery Strength
28
Disassociation
29
UCM Programming and Operation
30
Chapter Overview
30
Accessing Rover/Comm4
30
Rover Overview
30
Laptop Requirements and Complete Connection Instructions
30
UCM Home Tabs: at a Glance
33
Status Tab
34
Setpoints Tab
35
Wireless Tab
35
Advanced Configuration Tab
35
UCM Home Tabs: Instructions
36
Configuration
36
Setpoints Tab
36
Wireless Tab
43
Advanced Configuration Tab
43
Entering and Exiting the Service Mode
44
Overriding Vavs
45
Resetting Diagnostics
45
Downloading Program Files from PC to DDC UCM 4.2
46
Sequence of Operations
48
Chapter Overview
48
Single Duct Units
48
Override Conditions (Single Duct)
48
Fan-Powered Units
49
Parallel Fan-Powered Units
49
Occupied Units
49
Override Conditions (Parallel Fans)
50
Series Fan-Powered Units
51
Occupied Units
51
Override Conditions (Series Fan)
51
Zone Sensor Functions
52
Flow Sensor
53
Failure Modes
53
Air and Water Balancing
54
Chapter Overview
54
Air Balancing
54
System Checkout
54
System Setup
54
VAV Single Duct Unit Air Balancing
55
Water Balancing
57
Troubleshooting
58
Chapter Overview
58
Diagnostic Table
60
UCM Failure Procedures
60
UCM Communication Loss Procedures
60
Wired Zone Sensor Failure Procedures
61
Wired Zone Setpoint Failure Procedures
63
Airflow Failure Procedures
68
Auxiliary Temperature Sensor Failure Procedures
70
Auxiliary C02 Sensor Failure Procedures
71
VAV Damper Failure Procedures
72
VAV Series Fan Failure Procedures
73
VAV Parallel Fan Failure Procedures
73
VAV Electric Heat Stage(S) Failure Procedures
76
VAV Proportional Hot Water Failure
77
Trane/Honeywell Proportional Valve Check out Procedures
78
Cartridge Failure
78
Actuator Failure
78
VAV Two Position Hot Water Failure
78
Wiring Diagrams
79
Appendix
87
Advertisement
Advertisement
Related Products
Trane EDAB 4222A
Trane EDAB 4225A
Trane EDAB 4228A
Trane CASSETTE MCCE 42 2B5
Trane CASSETTE MCCE 42 2B
Trane NEW STYLUS MCXB 42 G1
Trane NEW STYLUS MCXB 42 G1E
Trane 4TWX8
Trane 4TVH0115FE000AA
Trane 4TTX6060J
Trane Categories
Air Conditioner
Heat Pump
Chiller
Air Handlers
Furnace
More Trane Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL