7-6. Adjustment of the XY table detector
XY table detecting position is front left corner of sawing area to the needle center. At the first origin
movement when turn the machine power on, XY table moves toward above position. After detection, XY
table is back to the home position as shown in the following figure.
NOTE When modify the home position somewhere other than the center of sewing area, please refer to
the instructions OPERATION PANEL technical manual [18] [Easy setting 3-(5)].
<4>
<1>
<3>
<2>
<5>
1000 (1200)
<5>
500 (600) 500(600)
(
) dimensions: for PLK-J12060
1000 (1200)
Home position
Detecting position
<1>: X detect plate <2>: X detector <3>: Y detect plate <4>: Y detector <5>: Needle